BLIND SPOT MONITOR SENSOR INSTALLATION

Note

Replace the blind spot monitor sensor if it has been dropped or subjected to a severe impact.


  1. INSTALL BLIND SPOT MONITOR SENSOR LH

  2. INSTALL BLIND SPOT MONITOR SENSOR RH

  3. INSTALL BLIND SPOT MONITOR COVER LH


    1. Engage the 3 claws to install the blind spot monitor cover LH.

  4. INSTALL BLIND SPOT MONITOR COVER RH


    1. Engage the 3 claws to install the blind spot monitor cover RH.

  5. INSTALL BLIND SPOT MONITOR SENSOR LH WITH COVER


    1. A01I0YM

      Install the blind spot monitor sensor LH with cover with the 3 nuts.

      Torque:
      10 N*m  { 102 kgf*cm, 7 ft.*lbf }
    2. Connect the connector.

  6. INSTALL BLIND SPOT MONITOR SENSOR RH WITH COVER


    1. A01I0NY

      Install the blind spot monitor sensor RH with cover with the 3 nuts.

      Torque:
      10 N*m  { 102 kgf*cm, 7 ft.*lbf }
    2. Connect the connector.

  7. INSTALL REAR BUMPER ASSEMBLY

    Click here

  8. PERFORM BLIND SPOT MONITOR BEAM AXIS INSPECTION

    Click here

  9. PERFORM BLIND SPOT MONITOR BEAM AXIS CONFIRMATION

    Click here

    SST
    09870-60000   ( 09870-60010 )
    09870-60040
  10. PERFORM DIAGNOSTIC SYSTEM CHECK

    Click here