INSPECT SHIFT SOLENOID VALVE SL
| *a | Shift Solenoid Valve SL |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
If the value is not as specified, replace the shift solenoid valve.
Connect a positive (+) lead from the battery to the terminal of the solenoid connector, and a negative (-) lead to the solenoid body, and check the operation of the valve.
Note
When using battery voltage during the inspection, do not bring the positive (+) and negative (-) tester probes too close to each other as a short circuit may occur.
| OK |
|---|
| The valve moves and makes an operating sound. |
If the operation cannot be done as specified, replace the shift solenoid valve.
INSPECT SHIFT SOLENOID VALVE (SLT, SLU, SL1, SL2, SL3, SL4)
| *a | Component without harness connected (Shift Solenoid Valve SLT, SLU, SL1, SL2, SL3, SL4) |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
If the value is not as specified, replace the shift solenoid valve.
Connect a positive (+) lead from the battery with a 21 W bulb to terminal 2 and a negative (-) lead to terminal 1 of the solenoid valve connector, and check the operation of the valve.
Note
When using battery voltage during the inspection, do not bring the positive (+) and negative (-) tester probes too close to each other as a short circuit may occur.
| OK |
|---|
| The valve moves and makes an operating sound. |
If the operation cannot be done as specified, replace the shift solenoid valve.