VACUUM SWITCHING VALVE (for ACIS) INSTALLATION


  1. INSTALL VACUUM SWITCHING VALVE ASSEMBLY (for ACIS)


    1. Install the vacuum hose clamp with the bolt.

      Torque:
      5.4 N*m  { 55 kgf*cm, 48 in.*lbf }
    2. Install the vacuum switching valve assembly with the bolt.

      Torque:
      9.0 N*m  { 92 kgf*cm, 80 in.*lbf }
    3. Connect the 2 vacuum hoses and connector.

    4. Connect the union to connector tube hose and wire harness clamp.