2GR-FE ENGINE CONTROL SERVICE DATA

Spark plug
Spark plug type DENSO made FK20HR11
Standard electrode gap for new spark plug 1.0 to 1.1 mm (0.0394 to 0.0433 in.)
Maximum electrode gap for used spark plug 1.4 mm (0.0551 in.)
Camshaft timing oil control valve assembly
Resistance at 20°C (68°F) 6.9 to 7.9 Ω
Throttle body
Resistance 2 (M+) - 1 (M-) 0.3 to 100 Ω at 20°C (68°F)
Vacuum switching valve (for Engine Mounting)
Resistance at 20°C (68°F) 19 to 21 Ω
Acceleration pedal sensor
Standard voltage (Accelerator Position No.1) Released 0.5 to 1.1 V
Depressed 2.6 to 4.5 V
Standard voltage (Accelerator Position No.2) Released 1.2 to 2.0 V
Depressed 3.4 to 4.8 V
Mass air flow meter
Resistance 1 (THA) - 2 (E2) 13.6 to 18.4 kΩ at -20°C (-4°F)
1 (THA) - 2 (E2) 2.21 to 2.69 kΩ at 20°C (68°F)
1 (THA) - 2 (E2) 0.49 to 0.67 kΩ at 60°C (140°F)
Crankshaft position sensor
Resistance Cold 1630 to 2740 Ω
Hot 2065 to 3225 Ω
Engine coolant temperature sensor
Resistance 20°C (68°F) 2.32 to 2.59 kΩ
80°C (176°F) 0.310 to 0.326 kΩ
Knock sensor
Resistance at 20°C (68°F) 120 to 280 kΩ
Air fuel ratio sensor
Resistance 1 (HA1A) - 2 (+B) 1.6 to 3.2 Ω at 20°C (68°F)
1 (HA1A) - 4 (A1A-) 10 kΩ or higher
Oxygen sensor

Resistance

(for Bank 1 Sensor 2)

2 (HT1B) - 1 (+B) 11 to 16 Ω at 20°C (68°F)
2 (HT1B) - 3 (E2) 10 kΩ or higher

Resistance

(for Bank 2 Sensor 2)

1 (HT2B) - 2 (+B) 11 to 16 Ω at 20°C (68°F)
1 (HT2B) - 4 (E2) 10 kΩ or higher
EFI MAIN relay
Specified Condition No. 1 integration relay B-1 - No. 1 integration relay A-8

Battery voltage is not applied between terminals C-7 and E-2

10 kΩ or higher

No. 1 integration relay B-1 - No. 1 integration relay A-8

Battery voltage is applied between terminals C-7 and E-2

Below 1 Ω

No. 1 integration relay B-1 - No. 1 integration relay C-3
No. 1 integration relay B-1 - No. 1 integration relay C-4
No. 1 integration relay B-1 - No. 1 integration relay C-6
No. 1 integration relay B-1 - No. 1 integration relay C-9
No. 1 integration relay B-1 - No. 1 integration relay C-10
A/F HTR relay
Specified Condition No. 1 integration relay A-6 - No. 1 integration relay D-1

Battery voltage is not applied between terminals A-8 and E-2

10 kΩ or higher

No. 1 integration relay A-6 - No. 1 integration relay D-1

Battery voltage is applied between terminals A-8 and E-2

Below 1 Ω

No. 1 integration relay A-7 - No. 1 integration relay D-1
IG2 relay
Specified Condition No. 1 integration relay A-1 - No. 1 integration relay D-3

Battery voltage is not applied between terminals C-8 and E-2

10 kΩ or higher

No. 1 integration relay A-1 - No. 1 integration relay D-3

Battery voltage is applied between terminals C-8 and E-2

Below 1 Ω

No. 1 integration relay A-3 - No. 1 integration relay D-3
No. 1 integration relay A-5 - No. 1 integration relay D-3
No. 1 integration relay C-1 - No. 1 integration relay D-3
No. 1 integration relay C-2 - No. 1 integration relay D-3
No. 1 integration relay C-5 - No. 1 integration relay D-3