УСТРОЙСТВО УПРАВЛЕНИЯ ПОДАЧЕЙ ВОЗДУХА В НЕЙТРАЛИЗАТОР (для моделей с вспомогательной системой подачи воздуха в нейтрализатор) УСТАНОВКА

PROCEDURE


  1. INSTALL AIR INJECTION CONTROL DRIVER ASSEMBLY


    1. Install the air injection control driver assembly with the 3 bolts.

      Torque:
      8.0 N*m  { 82 kgf*cm, 71 in.*lbf }
    2. Connect the 4 air injection control driver connectors.

    3. Connect the wire harness clamp.

    4. Connect the ground wire with the bolt.

      Torque:
      8.0 N*m  { 82 kgf*cm, 71 in.*lbf }
  2. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL

    Note