КЛАПАН ПЕРЕКЛЮЧЕНИЯ ПОДАЧИ ВОЗДУХА (для моделей с вспомогательной системой подачи воздуха в нейтрализатор) ПРОВЕРКА

PROCEDURE


  1. INSPECT AIR SWITCHING VALVE ASSEMBLY


    1. B001W5Z

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 5 20°C (68°F) 4.5 to 5.5 Ω
      1 - Body ground Always 1 MΩ or higher
      5 - Body ground

      Note

      When measuring the resistance, do not touch terminals 2, 3 and 4.

      If the result is not as specified, replace the air switching valve assembly.

    2. B001VSVE06
      Text in Illustration
      *a Air

      Check the operation of the air switching valve.


      1. Check that air does not flow from port A to port B.

        Note

        Make sure the applied pressure is 30 kPa (0.3 kgf/cm2, 4.4 psi) or less

        If the result is not as specified, replace the air switching valve assembly.

      2. B001XE9E06
        Text in Illustration
        *a Air

        Apply battery voltage to the connector, and check the air switching valve operation.

        OK
        Measurement Condition Specified Condition

        Battery positive (+) → Terminal 1

        Battery negative (-) → Terminal 5

        Air flows from port A to port B

        Note

        When applying voltage, do not touch terminals 2, 3 and 4.

        If the result is not as specified, replace the air switching valve assembly.