Click here

ПОДОГРЕВАЕМЫЙ КИСЛОРОДНЫЙ ДАТЧИК УСТАНОВКА

Click here
Click here Click here

PROCEDURE


  1. Click here

    INSTALL NO. 2 HEATED OXYGEN SENSOR (for Bank 1 Sensor 2)


    1. B001WGI

      Temporarily install the sensor to the exhaust pipe by hand.

    2. B001XP7E02

      Using SST, tighten the sensor.

      09224-00010
      without SST
      44 N*m 449 kgf*cm 32 ft.*lbf
      with SST
      40 N*m 408 kgf*cm 30 ft.*lbf
      Table 1. Text in Illustration
      *1 Fulcrum Length
      Tip:
      • Use a torque wrench with a fulcrum length of 300 mm (11.8 in.). If using a torque wrench with a length that is not 300 mm (11.8 in.), calculate the torque specification for the torque wrench and SST based on the "without SST" torque specification (Click here).

      • Make sure SST and the wrench are connected in a straight line.

  2. Click here

    INSTALL HEATED OXYGEN SENSOR (for Bank 2 Sensor 2)


    1. Temporarily install the sensor to the exhaust pipe by hand.

    2. B001XP7E02

      Using SST, tighten the sensor.

      09224-00010
      without SST
      44 N*m 449 kgf*cm 32 ft.*lbf
      with SST
      40 N*m 408 kgf*cm 30 ft.*lbf
      Table 2. Text in Illustration
      *1 Fulcrum Length
      Tip:
      • Use a torque wrench with a fulcrum length of 300 mm (11.8 in.). If using a torque wrench with a length that is not 300 mm (11.8 in.), calculate the torque specification for the torque wrench and SST based on the "without SST" torque specification (Click here).

      • Make sure SST and the wrench are connected in a straight line.

  3. Click here

    INSTALL FRONT EXHAUST PIPE ASSEMBLY

    Click here

  4. Click here

    INSTALL FRONT NO. 2 EXHAUST PIPE ASSEMBLY

    Click here

  5. Click here

    INSPECT FOR EXHAUST GAS LEAK

    Click here

  6. Click here

    INSTALL NO. 2 ENGINE UNDER COVER

    Click here