LIGHTING SYSTEM Hazard Warning Switch Circuit

Click here
Click here Click here
DTC Code DTC Name
  Hazard Warning Switch Circuit
Click here

DESCRIPTION

The combination meter receives a hazard warning signal switch information signal, and illuminates the turn signal lights.

Click here

WIRING DIAGRAM

Click here

PROCEDURE


  1. Click here

    READ VALUE USING GTS (HAZARD FLASHER SWITCH)


    1. Operate the GTS according to the display and select the "Data List".

      Table 1. Combination Meter
      Tester Display Measurement Item/Range Normal Condition Diagnostic Note
      Hazard Flasher Switch Hazard switch signal / ON or OFF

      ON: Hazard switch on

      OFF: Hazard switch off

      -

  2. Click here

    CHECK VEHICLE TYPE


    1. Check the vehicle type.

      Table 2. Result
      Result Proceed to
      w/ Navigation System A
      w/o Audio B
      for radio Receiver Type C

  3. Click here

    INSPECT MULTI-DISPLAY ASSEMBLY (HAZARD WARNING SIGNAL SWITCH)


    1. Remove the multi-display (Click here).

    2. Inspect the multi-display (Click here).


  4. Click here

    CHECK HARNESS AND CONNECTOR (MULTI-DISPLAY - COMBINATION METER AND BODY GROUND)


    1. Disconnect the F79 and F97 multi-display connectors.

    2. Disconnect the E120 combination meter connector.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      E120-11 (HZSW) - F97-12 (HAZ) Always Below 1 Ω
      F79-13 (GND1) - Body ground
      E120-11 (HZSW) or F97-12 (HAZ) - Body ground Always 10 kΩ or higher

    • OK

      REPLACE COMBINATION METER ASSEMBLY (Click here)

    • NG

      REPAIR OR REPLACE HARNESS OR CONNECTOR

  5. Click here

    INSPECT HAZARD WARNING SIGNAL SWITCH


    1. Remove the hazard warning signal switch (Click here).

    2. Inspect the hazard warning signal switch (Click here).


  6. Click here

    CHECK HARNESS AND CONNECTOR (HAZARD WARNING SIGNAL SWITCH - COMBINATION METER AND BODY GROUND)


    1. Disconnect the F130 hazard warning signal connector.

    2. Disconnect the E120 combination meter connector.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      E120-11 (HZSW) - F130-4 (F) Always Below 1 Ω
      F130-1 (E) - Body ground
      E120-11 (HZSW) or F130-4 (F) - Body ground Always 10 kΩ or higher

    • OK

      REPLACE COMBINATION METER ASSEMBLY (Click here)

    • NG

      REPAIR OR REPLACE HARNESS OR CONNECTOR

  7. Click here

    INSPECT CLOCK ASSEMBLY


    1. Remove the clock (Click here).

    2. Inspect the clock (Click here).


  8. Click here

    CHECK HARNESS AND CONNECTOR (CLOCK - COMBINATION METER AND BODY GROUND)


    1. Disconnect the g2 clock signal connector.

    2. Disconnect the E120 combination meter connector.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      E120-11 (HZSW) - g2-5 (F) Always Below 1 Ω
      g2-8 (E) - Body ground
      E120-11 (HZSW) or g2-5 (F) - Body ground Always 10 kΩ or higher

    • OK

      REPLACE COMBINATION METER ASSEMBLY (Click here)

    • NG

      REPAIR OR REPLACE HARNESS OR CONNECTOR