RELAY(w/ Headlight Cleaner System) ON-VEHICLE INSPECTION

PROCEDURE


  1. INSPECT HEADLIGHT CLEANER CONTROL RELAY


    1. A01X4DSE12
      Text in Illustration
      *a

      Component without harness connected

      (Headlight Cleaner Control Relay)

      w/o Washer Linked Operation:


      1. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        6 (B) - 4 (E) Battery voltage is not applied between terminals 3 (IG) and 2 (H) 10 kΩ or higher
        Battery voltage is applied between terminals 3 (IG) and 2 (H) Below 1 Ω (0.8 to 0.9 seconds, then no continuity exists)

        If the result is not as specified, replace the headlight cleaner control relay.

    2. A01X4DSE08
      Text in Illustration
      *a

      Component without harness connected

      (Headlight Cleaner Control Relay)

      w/ Washer Linked Operation:


      1. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        6 (B) - 4 (E) Battery voltage not applied 10 kΩ or higher

        Battery positive (+) → Terminal 3 (IG)

        Battery negative (-) → Terminal 4 (E)

        Battery negative (-) → Terminal 5 (FRWA)

        Battery positive (+) → Terminal 3 (IG)

        Battery positive (+) → Terminal 2 (H)

        Battery negative (-) → Terminal 4 (E)

        Below 1 Ω for 0.8 to 0.9 seconds, then resistance increases by large amount

        Battery positive (+) → Terminal 3 (IG)

        Battery positive (+) → Terminal 1 (HDLO)

        Battery negative (-) → Terminal 4 (E)

        Battery negative (-) → Terminal 5 (FRWA)

        If the result is not as specified, replace the headlight cleaner control relay.