OUTER MIRROR SWITCH INSPECTION

PROCEDURE


  1. INSPECT OUTER MIRROR SWITCH ASSEMBLY (w/ Power Retract Mirror)

    A01X5YYE03
    Text in Illustration
    *1 Left/Right Adjustment Switch
    *2 Retract Switch
    *3 Mirror Surface Adjustment Switch
    *a

    Component without harness connected

    (Outer Mirror Switch Assembly)


    1. Inspect the retract switch.


      1. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Switch Condition Specified Condition
        22 (MF) - 20 (E) Pushed in 10 kΩ or higher
        Not pushed in Below 1 Ω

        If the result is not as specified, replace the outer mirror switch assembly.

    2. Inspect the left/right adjustment switch.


      1. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Switch Condition Specified Condition
        13 (MSW) - 14 (E) R Below 10 Ω
        OFF 10 kΩ or higher
        L 90 to 110 Ω

        If the result is not as specified, replace the outer mirror switch assembly.

    3. Inspect the mirror surface adjustment switch.


      1. Select "L" on the left/right adjustment switch.

      2. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Switch Condition Specified Condition
        16 (M+) - 14 (E) UP Pressed 90 to 110 Ω
        Not pressed 10 kΩ or higher
        DOWN Pressed 437 to 503 Ω
        Not pressed 10 kΩ or higher
        LEFT Pressed 744 to 856 Ω
        Not pressed 10 kΩ or higher
        RIGHT Pressed 225 to 275 Ω
        Not pressed 10 kΩ or higher

        If the result is not as specified, replace the outer mirror switch assembly.

      3. Select "R" on the left/right adjustment switch.

      4. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Switch Condition Specified Condition
        16 (M+) - 14 (E) UP Pressed 90 to 110 Ω
        Not pressed 10 kΩ or higher
        DOWN Pressed 437 to 503 Ω
        Not pressed 10 kΩ or higher
        LEFT Pressed 744 to 856 Ω
        Not pressed 10 kΩ or higher
        RIGHT Pressed 225 to 275 Ω
        Not pressed 10 kΩ or higher

        If the result is not as specified, replace the outer mirror switch assembly.

    4. Inspect the switch illumination.

      Apply battery voltage between the terminals of the light, and check the operation of the light.

      OK
      Measurement Condition Specified Condition

      Battery positive (+) → Terminal 23 (ILL+)

      Battery negative (-) → Terminal 24 (ILL-)

      Light comes on

      If the result is not as specified, replace the outer mirror switch assembly.

  2. INSPECT OUTER MIRROR SWITCH ASSEMBLY (w/o Power Retract Mirror)

    A01X5WJE02
    Text in Illustration
    *1 Left/Right Adjustment Switch
    *2 Mirror Surface Adjustment Switch
    *a

    Component without harness connected

    (Outer Mirror Switch Assembly)


    1. Inspect the left/right adjustment switch and mirror surface adjustment switch.


      1. Select "L" on the left/right adjustment switch.

      2. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Switch Condition Specified Condition

        9 (MLV) - 11 (B)

        6 (M+) - 12 (E)

        UP Pressed Below 1 Ω
        Not pressed 10 kΩ or higher

        9 (MLV) - 12 (E)

        6 (M+) - 11 (B)

        DOWN Pressed Below 1 Ω
        Not pressed 10 kΩ or higher

        10 (MLH) - 11 (B)

        6 (M+) - 12 (E)

        LEFT Pressed Below 1 Ω
        Not pressed 10 kΩ or higher

        10 (MLH) - 12 (E)

        6 (M+) - 11 (B)

        RIGHT Pressed Below 1 Ω
        Not pressed 10 kΩ or higher

        If the result is not as specified, replace the outer mirror switch assembly.

      3. Select "R" on the left/right adjustment switch.

      4. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Switch Condition Specified Condition

        8 (MRV) - 11 (B)

        6 (M+) - 12 (E)

        UP Pressed Below 1 Ω
        Not pressed 10 kΩ or higher

        8 (MRV) - 12 (E)

        6 (M+) - 11 (B)

        DOWN Pressed Below 1 Ω
        Not pressed 10 kΩ or higher

        7 (MRH) - 11 (B)

        6 (M+) - 12 (E)

        LEFT Pressed Below 1 Ω
        Not pressed 10 kΩ or higher

        7 (MRH) - 12 (E)

        6 (M+) - 11 (B)

        RIGHT Pressed Below 1 Ω
        Not pressed 10 kΩ or higher

        If the result is not as specified, replace the outer mirror switch assembly.

    2. Inspect the switch illumination.

      Apply battery voltage between the terminals of the light, and check the operation of the light.

      OK
      Measurement Condition Specified Condition

      Battery positive (+) → Terminal 15 (ILL+)

      Battery negative (-) → Terminal 16 (ILL-)

      Light comes on