PTC HEATER ASSEMBLY INSPECTION

PROCEDURE


  1. INSPECT QUICK HEATER ASSEMBLY


    1. A01X2ZFE02
      Text in Illustration
      *1 Connector A
      *2 Connector B
      *3 Connector C
      *a

      Component without harness connected

      (Quick Heater Assembly)

      for 840W:

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      A-1 - B-1 23 to 25°C (73 to 77°F) 0.5 to 2.5 Ω
      A-2 - B-1 23 to 25°C (73 to 77°F) 0.5 to 2.5 Ω
      A-2 - C-1 23 to 25°C (73 to 77°F) 0.5 to 2.5 Ω
      A-3 - C-1 23 to 25°C (73 to 77°F) 0.5 to 2.5 Ω

      If the result is not as specified, replace the quick heater assembly.

    2. A01X2FQE05
      Text in Illustration
      *1 Connector A
      *2 Connector B
      *a

      Component without harness connected

      (Quick Heater Assembly)

      for 600W:

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      A1 - B1 23 to 25°C (73 to 77°F) 0.5 to 2.5 Ω
      A2 - B1 23 to 25°C (73 to 77°F) 0.5 to 2.5 Ω
      A2 - B2 23 to 25°C (73 to 77°F) 0.5 to 2.5 Ω
      A3 - B2 23 to 25°C (73 to 77°F) 0.5 to 2.5 Ω

      • If the result is not as specified, replace the quick heater assembly.

        Text in Illustration
        *1 Connector A
        *2 Connector B
        *a

        Component without harness connected

        (Quick Heater Assembly)