AIR CONDITIONING SYSTEM(for Manual Air Conditioning System) IG Power Source Circuit

DESCRIPTION

The main power source is supplied to the air conditioning amplifier assembly when the ignition switch is turned to ON. The power source is used for operating the air conditioning amplifier assembly, servo motors, etc.

WIRING DIAGRAM

A01X4W3E18
*a from IG1 Relay
*b A/C COMP
*c Air Conditioning Amplifier Assembly

CAUTION / NOTICE / HINT

Note

Inspect the fuses and relays for circuits related to this system before performing the following inspection procedure.

PROCEDURE


  1. CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER - BATTERY AND BODY GROUND)


    1. A01X5A2E01
      Text in Illustration
      *a

      Rear view of wire harness connector

      (to Air Conditioning Amplifier Assembly)

      Disconnect the air conditioning amplifier assembly connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      E81-14 (GND) - Body ground Always Below 1 Ω
    3. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Switch Condition Specified Condition
      E81-1 (IG+) - Body ground Ignition switch off Below 1 V
      Ignition switch ON 11 to 14 V

    OK
    NG