| DTC Code | DTC Name |
|---|---|
| B1412 | Ambient Temperature Sensor Circuit |
DESCRIPTION
The cooler thermistor (ambient temperature sensor) is installed in the front part of the cooler condenser assembly. This sensor is connected to the air conditioning amplifier assembly and detects fluctuations in the ambient temperature. The sensor sends a signal to the air conditioning amplifier assembly. The resistance of the cooler thermistor (ambient temperature sensor) changes in accordance with the ambient temperature. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.
The air conditioning amplifier assembly applies a voltage (5 V) to the cooler thermistor (ambient temperature sensor) and reads voltage changes as changes in the resistance of the cooler thermistor (ambient temperature sensor).
| DTC Code | DTC Detection Condition | Trouble Area |
|---|---|---|
| B1412 | An open or short in the cooler thermistor (ambient temperature sensor) circuit is detected for 8.5 minutes or more. |
|
WIRING DIAGRAM
| *a | Cooler Thermistor (Ambient Temperature Sensor) |
| *b | Air Conditioning Amplifier Assembly |
PROCEDURE
READ VALUE USING INTELLIGENT TESTER (AMBIENT TEMP SENSOR)
Use the Data List to check if the cooler thermistor (ambient temperature sensor) is functioning properly Click here.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
|---|---|---|---|
| Ambient Temp Sensor | Cooler thermistor (ambient temperature sensor) / Min: -23.3°C (-9.94°F) Max: 65.95°C (150.71°F) |
Actual ambient temperature displayed | Open in the circuit: -23.3°C (-9.94°F). Short in the circuit: 65.95°C (150.71°F). |
| OK |
|---|
| The display is as specified in the normal condition column. |
| Result | Proceed to |
|---|---|
| OK (When troubleshooting according to problem symptoms table) | A |
| OK (When troubleshooting according to the DTC) | B |
| NG | C |
| A |
|
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE Click here |
| B |
|
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY Click here |
| C |
|
INSPECT COOLER THERMISTOR (AMBIENT TEMPERATURE SENSOR)
Remove the cooler thermistor (ambient temperature sensor) Click here.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
| *a | Sensing Portion |
| *b | Resistance |
| *c | Allowable Range |
| *d | Temperature |
Note
Even slightly touching the sensor may change the resistance value. Be sure to hold the connector of the sensor.
When measuring, the sensor temperature must be the same as the ambient temperature.
Tech Tips
As the temperature increases, the resistance decreases (refer to the graph).
| NG |
|
REPLACE COOLER THERMISTOR (AMBIENT TEMPERATURE SENSOR) Click here |
| OK |
|
CHECK HARNESS AND CONNECTOR (COOLER THERMISTOR - AIR CONDITIONING AMPLIFIER)
Disconnect the A14 cooler thermistor (ambient temperature sensor) connector.
Disconnect the E81 air conditioning amplifier assembly connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
| OK |
|
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY Click here |
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |