AIR CONDITIONING SYSTEM(for Manual Air Conditioning System), Diagnostic DTC:B1443/43

DTC Code DTC Name
B1443/43 Air Outlet Damper Control Servo Motor Circuit

DESCRIPTION

The mode damper servo motor sends pulse signals to inform the air conditioning amplifier assembly of the damper position. The air conditioning amplifier assembly activates the motor (normal or reverse) based on the signals to move the mode damper servo motor to any position, which controls the air outlet changes.

Tech Tips

Confirm that no mechanical problem is present because this trouble code can be output when either a damper link or damper is mechanically locked.

DTC Code DTC Detection Condition Trouble Area
B1443/43 The air outlet damper position does not change even if the air conditioning amplifier assembly operates the air outlet damper servo motor.
  • Mode damper servo motor

  • Air conditioning harness assembly

  • Air conditioning amplifier assembly

WIRING DIAGRAM

B001WOVE62

PROCEDURE


  1. READ VALUE USING GTS (AIR OUTLET SERVO PULSE [D], AIR OUTLETSERVO ACTU PULSE[D])


    1. Use the Data List to check if the mode damper servo motor is functioning properly Click here.

      Air Conditioner
      Tester Display Measurement Item/Range Normal Condition Diagnostic Note
      Air Outlet Servo Pulse (D) Mode damper servo motor target pulse / Min.: 128, Max.: 383
      • FACE: 254 (pulse)

      • FACE1: 246 (pulse)

      • FACE2: 254 (pulse)

      • B/L1: 230 (pulse)

      • B/L2: 218 (pulse)

      • FOOT-O: 208 (pulse)

      • FOOT-D: 189 (pulse)

      • FOOT-R: 178 (pulse)

      • FOOT-F: 178 (pulse)

      • FOOT 178 (pulse)

      • F/D: 155 (pulse)

      • DEF: 143 (pulse)


      • Displayed between 143 and 254 pulse

      • Mode damper servo motor system malfunction

      Air Outlet Servo Actu Pulse(D) Mode damper servo motor actual pulse / Min.: 128, Max.: 383
      • FACE: 254 (pulse)

      • FACE1: 246 (pulse)

      • FACE2: 254 (pulse)

      • B/L1: 230 (pulse)

      • B/L2: 218 (pulse)

      • FOOT-O: 208 (pulse)

      • FOOT-D: 189 (pulse)

      • FOOT-R: 178 (pulse)

      • FOOT-F: 178 (pulse)

      • FOOT 178 (pulse)

      • F/D: 155 (pulse)

      • DEF: 143 (pulse)


      • Displayed between 143 and 254 pulse

      • Mode damper servo motor LH system malfunction

      OK
      When the driver side mode switch is turned, the actual pulse changes following the target pulse.
      Result
      Result Proceed to
      Target pulse changes but actual pulse does not change A
      Target pulse and actual pulse do not change B
      Actual pulse changes following the target pulse (When troubleshooting according to the DTC) C
      Actual pulse changes following the target pulse (When troubleshooting according to Problem Symptoms Table) D

    B
    C
    D
    A
  2. CHECK MODE DAMPER SERVO MOTOR


    1. Replace the mode damper servo motor.


      Tech Tips

      Since the servo motor cannot be inspected while it is removed from the vehicle, replace the servo motor with a normal one.

    2. Clear the DTCs Click here.

    3. Check for DTCs Click here.

      OK
      DTC B1443/43 is not output.

    OK
    B
  3. CHECK AIR CONDITIONING HARNESS ASSEMBLY


    1. Replace the air conditioning harness assembly with a new or known good one.


    2. Clear the DTCs Click here.

    3. Check for DTCs Click here.

      OK
      DTC B1443/43 is not output.

    OK
    NG
  4. CHECK FOR DTC


    1. Clear the DTCs Click here.

    2. Check for DTCs Click here.

      OK
      DTC B1443/43 is not output.

    OK
    NG