AIR CONDITIONING SYSTEM(for Automatic Air Conditioning System) Cooling Box Blower Motor Circuit

DESCRIPTION

The cooler blower motor is operated by signals from the air conditioning amplifier assembly (for cool box).

WIRING DIAGRAM

A01XB10E11

CAUTION / NOTICE / HINT

Note

Inspect the fuses for circuits related to this system before performing the following inspection procedure.

PROCEDURE


  1. CHECK HARNESS AND CONNECTOR (NO. 1 COOLER WIRING HARNESS SUB-ASSEMBLY - BATTERY)


    1. A01XALPE03
      Text in Illustration
      *a

      Front view of wire harness connector

      (to No. 1 Cooler Wiring Harness Sub-assembly)

      Disconnect the No. 1 cooler wiring harness sub-assembly connector.

    2. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Switch Condition Specified Condition
      1 - Body ground Ignition switch off Below 1 V
      Ignition switch ON 11 to 14 V

    NG
    OK
  2. CHECK HARNESS AND CONNECTOR (NO. 1 COOLER WIRING HARNESS SUB-ASSEMBLY - BODY GROUND)


    1. A01XALPE03
      Text in Illustration
      *a

      Front view of wire harness connector

      (to No. 1 Cooler Wiring Harness Sub-assembly)

      Disconnect the No. 1 cooler wiring harness sub-assembly connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      6 - Body ground Always Below 1 Ω

    NG
    OK
  3. CHECK NO. 1 COOLER WIRING HARNESS SUB-ASSEMBLY


    1. Replace the No. 1 cooler wiring harness sub-assembly with a normal one and check that the condition returns to normal.

      OK
      Same problem does not occur.

    OK
    NG
  4. INSPECT COOL BOX BLOWER WITH FAN MOTOR SUB-ASSEMBLY


    1. Remove the cool box blower with fan motor sub-assembly Click here.

    2. Inspect the cool box blower with fan motor sub-assembly Click here.

      OK
      Cooler blower motor operates smoothly.

    OK
    NG