AIR CONDITIONING SYSTEM(for Automatic Air Conditioning System) DATA LIST / ACTIVE TEST

Tech Tips

Using the intelligent tester to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.

Note

In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.


  1. DATA LIST


    1. Connect the intelligent tester to the DLC3.

    2. Turn the engine switch on (IG).

    3. Turn the intelligent tester on.

    4. Enter the following menus: Body / Air Conditioner / Data List.

    5. Enter the following menus: Powertrain / Engine and ECT / Data List.

    6. According to the display on the intelligent tester, read the Data List.

      Air Conditioner
      Tester Display Measurement Item/Range Normal Condition Diagnostic Note
      Room Temperature Sensor

      Front room temperature sensor /

      Min.: -6.5°C (20.3°F)

      Max.: 57.25°C (135.05°F)

      Actual room temperature for front seat displayed

      Open in the circuit: -6.5°C (20.3°F).

      Short in the circuit: 57.25°C (135.05°F).

      Ambient Temp Sensor

      Ambient temperature sensor /

      Min.: -23.3°C (-9.94°F)

      Max.: 65.95°C (150.71°F)

      Actual ambient temperature displayed

      Open in the circuit: -23.3°C (-9.94°F).

      Short in the circuit: 65.95°C (150.71°F).

      Adjusted Ambient Temp

      Adjusted ambient temperature /

      Min.: -30.8°C (-23.44°F)

      Max.: 50.8°C (123.44°F)

      Adjusted ambient temperature displayed -
      Evaporator Fin Thermistor

      No. 1 cooler thermistor /

      Min.: -29.7°C (-21.46°F)

      Max.: 59.55°C (139.19°F)

      Actual evaporator temperature displayed

      Open in the circuit: -29.7°C (-21.46°F).

      Short in the circuit: 59.55°C (139.19°F).

      Evaporator Target Temp

      Target evaporator temperature /

      Min.: 1.5°C (34.7°F)

      Max.: 4.0°C (39.2°F)

      Target evaporator temperature displayed -
      Solar Sensor (D Side)

      Driver side solar sensor /

      Min.: 0, Max.: 255

      Driver side solar sensor voltage increases as brightness increases

      Open in the circuit: 0

      Short in the circuit: 255

      Solar Sensor (P Side)

      Passenger side solar sensor /

      Min.: 0, Max.: 255

      Passenger side solar sensor voltage increases as brightness increases

      Open in the circuit: 0

      Short in the circuit: 255

      Engine Coolant Temp

      Engine coolant temperature /

      Min.: 1.3°C (34.34°F)

      Max.: 90.55°C (194.99°F)

      Actual engine coolant temperature displayed while engine warmed up -
      Set Temperature (D Side)

      Driver side set temperature /

      MAX COLD: 15.5°C (59.9°F)

      MAX HOT: 32.5°C (90.5°F)

      Driver side actual set temperature displayed -
      Set Temperature (P Side)

      Passenger side set temperature /

      MAX COLD: 15.5°C (59.9°F)

      MAX HOT: 32.5°C (90.5°F)

      Passenger side actual set temperature displayed -
      A/M Servo Targ Pulse (Rear D)

      Rear air mix damper servo motor target pulse /

      Min.: 9, Max.: 54 (for LHD)

      Min.: 8, Max.: 53 (for RHD)

      for LHD


      • MAX COOL: 9 (pulse)

      • MAX HOT: 54 (pulse)

      for RHD


      • MAX COOL: 53 (pulse)

      • MAX HOT: 8 (pulse)

      -
      A/M Servo Targ Pulse (Rear P)

      Rear air mix damper servo motor (for front passenger side) target pulse /

      Min.: 8, Max.: 53 (for LHD)

      Min.: 9, Max.: 54 (for RHD)

      for LHD


      • MAX COOL: 53 (pulse)

      • MAX HOT: 8 (pulse)

      for RHD


      • MAX COOL: 9 (pulse)

      • MAX HOT: 54 (pulse)

      -
      Hand Free Telephone Handsfree telephone / OFF or ON

      ON: Handsfree telephone used

      OFF: Handsfree telephone not used

      -
      Blower Motor Speed Level

      Blower motor speed level /

      Min.: 0 level,

      Max.: 31 level

      Increases in range between 0 and 31 as blower motor speed increases -
      Regulator Pressure Sensor

      Refrigerant pressure sensor /

      Min.: -0.4566 MPaG

      Max.: 3.2943 MPaG

      Actual refrigerant pressure displayed -
      Room Temp Sensor (Rear)

      Rear room temperature sensor /

      Min.: -6.5°C (20.3°F)

      Max.: 57.25°C (135.05°F)

      Actual rear room temperature displayed

      Open in the circuit: -6.5°C (20.3°F).

      Short in the circuit: 57.25°C (135.05°F).

      Ambient Temp Sens (Rear)

      No. 2 cooler thermistor /

      Min.: -29.7°C (-21.46°F)

      Max.: 59.55°C (139.19°F)

      Actual rear evaporator temperature displayed

      Open in the circuit: -29.7°C (-21.46°F).

      Short in the circuit: 59.55°C (139.19°F).

      Blower Motor Level (Rear)

      Rear blower motor speed level /

      Min.: 0, Max.: 31

      Increases in range between 0 to 31 as rear blower motor speed increases -
      Air Mix Servo Targ Pulse(D)

      Air mix damper servo motor (for driver side) target pulse /

      Min.: 8, Max.: 90 (for LHD)

      Min.: 8, Max.: 90 (for RHD)

      for LHD


      • MAX COOL: 90 (pulse)

      • MAX HOT: 8 (pulse)

      for RHD


      • MAX COOL: 8 (pulse)

      • MAX HOT: 90 (pulse)

      -
      Air Mix Servo Targ Pulse(P)

      Air mix damper servo motor (for front passenger side) target pulse /

      Min.: 8, Max.: 90 (for LHD)

      Min.: 8, Max.: 90 (for RHD)

      for LHD


      • MAX COOL: 8 (pulse)

      • MAX HOT: 90 (pulse)

      for RHD


      • MAX COOL: 90 (pulse)

      • MAX HOT: 8 (pulse)

      -
      Air Inlet Damper Targ Pulse

      REC/FRS damper servo motor target pulse /

      Min.: 9, Max.: 37

      for LHD

      Recirculation: 37 (pulse)

      Fresh: 9 (pulse)

      for RHD

      Recirculation: 9 (pulse)

      Fresh: 37 (pulse)

      -
      Cool Air Bypass Pulse

      Cool air bypass damper servo motor target pulse /

      Min.: 6, Max.: 57

      Shut: 6 (pulse)

      Open: 57 (pulse)

      -
      Electric Heater Count

      Electric heater count /

      Min.: 0, Max.: 3

      - -
      Shift Set Temperature Shift set temperature / +2 C, +1 C, NORMAL, -1 C, -2 C Customized value displayed -
      Air Inlet Mode Air inlet mode / AUTO, MANUAL Customized value displayed -
      Compressor Mode Compressor mode / AUTO, MANUAL Customized value displayed -
      Compressor/DEF Mode Compressor/DEF mode / LINK, NORMAL Customized value displayed -
      Evaporator Control Evaporator control / AUTO, MANUAL Customized value displayed -
      Button Press Buzzer Button press buzzer / ON or OFF Customized value displayed -
      Foot/DEF Auto Mode FOOT/DEF auto mode / ON or OFF Customized value displayed -
      Foot/DEF Auto Blow Up FOOT/DEF auto blower up function / ON or OFF Customized value displayed -
      Filter Sensor Filter sensor / LESS, NORMAL, MORE Customized value displayed -
      Rear A/P HI Set Rear A/P HI set / ON or OFF Customized value displayed -
      Ambient Temperature Shift Ambient temperature shift / +3 C, +2 C, +1 C, NORMAL, -1 C, -2 C, -3 C Customized value displayed -
      A/O Damper FACE Pos(D)

      Air outlet damper servo motor (for driver side mode) target pulse /

      Min.: 6, Max.: 117

      FACE1: 117 (pulse)

      FACE2: 109 (pulse)

      B/L1: 93 (pulse)

      B/L2: 81 (pulse)

      FOOT-F: 41 (pulse)

      FOOT-R: 41 (pulse)

      FOOT-D: 52 (pulse)

      F/D: 18 (pulse)

      DEF: 6 (pulse)

      -
      A/O Damper FACE Pos(P)

      Air outlet damper servo motor (for front passenger side mode) target pulse /

      Min.: 6, Max.: 117 (for LHD)

      Min.: 9, Max.: 120 (for RHD)

      for LHD


      • FACE1: 117 (pulse)

      • FACE2: 109 (pulse)

      • B/L1: 93 (pulse)

      • B/L2: 81 (pulse)

      • FOOT-F: 41 (pulse)

      • FOOT-R: 41 (pulse)

      • FOOT-D: 52 (pulse)

      • F/D: 18 (pulse)

      • DEF: 6 (pulse)

      for RHD


      • FACE1: 9 (pulse)

      • FACE2: 17 (pulse)

      • B/L1: 33 (pulse)

      • B/L2: 45 (pulse)

      • FOOT-F: 85 (pulse)

      • FOOT-R: 85 (pulse)

      • FOOT-D: 74 (pulse)

      • F/D: 108 (pulse)

      • DEF: 120 (pulse)

      -
      Air Mix Servo Targ Pls(F&R D)

      Front air mix damper servo motor (for driver side rear air flow) target pulse /

      Min.: 13, Max.: 41 (for LHD)

      Min.: 5, Max.: 33 (for RHD)

      for LHD


      • MAX COOL: 13 (pulse)

      • MAX HOT: 41 (pulse)

      for RHD


      • MAX COOL: 33 (pulse)

      • MAX HOT: 5 (pulse)

      -
      Air Mix Servo Targ Pls(F&R P)

      Front air mix damper servo motor (for front passenger side rear air flow) target pulse /

      Min.: 5, Max.: 33 (for LHD)

      Min.: 13, Max.: 41 (for RHD)

      for LHD


      • MAX COOL: 33 (pulse)

      • MAX HOT: 5 (pulse)

      for RHD


      • MAX COOL: 13 (pulse)

      • MAX HOT: 41 (pulse)

      -
      Air Outlet Servo Pls (F&R D)

      Air outlet damper servo motor (for rear seat mode) target pulse /

      Min.: 9, Max.: 79

      FACE1: 9 (pulse)

      B/L1: 28 (pulse)

      FOOT-O: 41 (pulse)

      F/D: 67 (pulse)

      DEF: 79 (pulse)

      -
      Air Outlet Servo Pulse (R)

      Rear air outlet damper servo motor target pulse /

      Min.: 7, Max.: 83

      FOOT: 7 (pulse)

      B/L: 42 (pulse)

      FACE: 83 (pulse)

      -
      Room Temperature Sensor (RP)

      Rear room temperature sensor /

      Min.: -6.5°C (20.3°F)

      Max.: 57.25°C (135.05°F)

      Actual rear room temperature displayed

      Open in the circuit: -6.5°C (20.3°F)

      Short in the circuit: 57.25°C (135.05°F)

      Set Temperature (Rear D side)

      Rear driver side set temperature /

      MAX COLD: 0°C (32°F)

      MAX HOT: 32°C (54°F)

      Rear driver side actual set temperature displayed -
      Set Temperature (Rear P side)

      Rear passenger side set temperature /

      MAX COLD: 0°C (32°F)

      MAX HOT: 32°C (54°F)

      Rear passenger side actual set temperature displayed -
      Foot Duct Sensor(Rear D)

      Min.: -12.7°C (9.14°F)

      Max.: 76.55°C (169.79°F)

      Actual air duct temperature sensor (for driver side) displayed

      Open in the circuit: -12.7°C (9.14°F)

      Short in the circuit: 76.55°C (169.79°F)

      Foot Duct Sensor(Rear P)

      Min.: -12.7°C (9.14°F)

      Max.: 76.55°C (169.79°F)

      Actual air duct temperature sensor (for passenger side) displayed

      Open in the circuit: -12.7°C (9.14°F)

      Short in the circuit: 76.55°C (169.79°F)

      Number of Trouble Codes

      Number of trouble codes /

      Min.: 0, Max.: 255

      Number of DTCs displayed -
      A/O Damper FOOT/DEF Pos(P)

      Air outlet damper servo motor (for DEF mode) target pulse /

      Min.: 6, Max.: 117


      • FACE1: 117 (pulse)

      • FACE2: 109 (pulse)

      • B/L1: 93 (pulse)

      • B/L2: 81 (pulse)

      • FOOT-D: 52 (pulse)

      • FOOT-R: 41 (pulse)

      • FOOT-F: 41 (pulse)

      • F/D: 18 (pulse)

      • DEF: 6 (pulse)

      -
      Engine
      Tester Display Measurement Item/Range Normal Condition Diagnostic Note
      A/C Signal A/C signal / ON or OFF

      ON: A/C Switch on

      OFF: A/C Switch off

      -
  2. ACTIVE TEST

    Tech Tips

    Using the intelligent tester to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.


    1. Connect the intelligent tester to the DLC3.

    2. Turn the engine switch on (IG).

    3. Turn the intelligent tester on.

    4. Enter the following menus: Body / Air Conditioner / Active Test.

    5. According to the display on the intelligent tester, perform the Active Test.

      Tester Display Test Part Control Range Diagnostic Note
      Blower Motor Front blower motor Min.: 0, Max.: 31 -
      Magnetic Clutch Relay Magnetic clutch relay OFF or ON -
      Air Mix Servo Targ Pulse(D) Air mix servo motor pulse (Front A/C D side) Min.: 8, Max.: 90 -
      Air Mix Servo Targ Pulse(P) Air mix servo motor pulse (Front A/C P side) Min.: 8, Max.: 90 -
      Air Inlet Damper Targ Pulse Air inlet damper target pulse Min.: 9, Max.: 37 -
      Cool Air Bypass Pulse Driver side cool air bypass pulse Min.: 6, Max.: 57 -
      Rear Blower Motor Rear blower motor Min.: 0, Max.: 31 -
      Rear Air Mix Servo Targ Pulse Rear air mix damper servo motor pulse

      for LHD

      Min.: 9, Max.: 54

      for RHD

      Min.: 8, Max.: 53

      -
      DEF A/O Servo Pulse(D) Rear air outlet damper servo motor pulse Min.: 7, Max.: 83 -
      Rear A/M Servo Pulse(P) Rear air mix damper servo motor (for front passenger side) pulse

      for LHD

      Min.: 8, Max.: 53

      for RHD

      Min.: 9, Max.: 54

      -
      Rear A/C Mag Valve Rear A/C magnetic valve OFF or ON -
      Face A/O Servo Pulse(D) Air outlet servo motor pulse (D side) Min.: 6, Max.: 117 -
      Face A/O Servo Pulse(P) Air outlet servo motor pulse (P side)

      for LHD

      Min.: 6, Max.: 117

      for RHD

      Min.: 9, Max.: 120

      -
      A/M Servo Puls(F&R D) Air mix servo motor pulse (Front A/C rear air flow D side)

      for LHD

      Min.: 9, Max.: 54

      for RHD

      Min.: 8, Max.: 53

      -
      A/M Servo Puls(F&R P) Air mix servo motor pulse (Front A/C rear air flow P side)

      for LHD

      Min.: 8, Max.: 53

      for RHD

      Min.: 9, Max.: 54

      -
      A/O Servo Pulse(F&R D) Air outlet servo motor pulse (Front A/C rear air flow D side) Min.: 9, Max.: 79 -
      A/O Servo Pulse(Rr D) Air outlet servo motor pulse (Rr D side) Min.: 7, Max.: 83 -