FRONT SEAT CUSHION HEATER INSPECTION

PROCEDURE


  1. INSPECT FRONT SEAT CUSHION HEATER ASSEMBLY LH (w/o Climate Control Seat System)

    A01WZCCE01
    Text in Illustration
    *1 Thermostat
    *2 Connector A
    *3 Connector B
    *a

    Component without harness connected

    (Front Seat Cushion Heater Assembly LH)


    1. Check the front seat cushion heater assembly LH.


      1. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Front Seat Cushion Heater Assembly LH
        Tester Connection Condition Specified Condition

        A1 - A4

        A1 - B1

        A4 - B2

        B1 - B2

        Seat cushion heater temperature 25°C (77°F) 2.5 to 3.0 Ω
        A2 - A3 8 to 12 kΩ
      2. Heat the thermostat with a light.

      3. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Thermostat
        Tester Connection Condition Specified Condition

        A1 - A4

        A1 - B1

        A1 - B2

        46 to 54°C or more 10 kΩ or higher

        If the result is not as specified, replace the front seat cushion heater assembly LH.

  2. INSPECT FRONT SEAT CUSHION HEATER ASSEMBLY LH (w/ Climate Control Seat System)

    A01X9R3E01
    Text in Illustration
    *1 Thermostat
    *2 Connector A
    *3 Connector B
    *a

    Component without harness connected

    (Front Seat Cushion Heater Assembly LH)


    1. Check the front seat cushion heater assembly LH.


      1. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Front Seat Cushion Heater Assembly LH
        Tester Connection Condition Specified Condition

        A1 - A3

        A1 - B1

        A3 - B2

        B1 - B2

        Seat cushion heater temperature 25°C (77°F) 2.5 to 3.0 Ω
        A2 - A3 8 to 12 kΩ
      2. Heat the thermostat with a light.

      3. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Thermostat
        Tester Connection Condition Specified Condition

        A1 - A3

        A1 - B1

        A1 - B2

        46 to 54°C or more 10 kΩ or higher

        If the result is not as specified, replace the front seat cushion heater assembly LH.

  3. INSPECT FRONT SEAT CUSHION HEATER ASSEMBLY RH (w/o Climate Control Seat System)

    A01WZCCE01
    Text in Illustration
    *1 Thermostat
    *2 Connector A
    *3 Connector B
    *a

    Component without harness connected

    (Front Seat Cushion Heater Assembly RH)


    1. Check the front seat cushion heater assembly RH.


      1. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Front Seat Cushion Heater Assembly RH
        Tester Connection Condition Specified Condition

        A1 - A4

        A1 - B1

        A4 - B2

        B1 - B2

        Seat cushion heater temperature 25°C (77°F) 2.5 to 3.0 Ω
        A2 - A3 8 to 12 kΩ
      2. Heat the thermostat with a light.

      3. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Thermostat
        Tester Connection Condition Specified Condition

        A1 - A4

        A1 - B1

        A1 - B2

        46 to 54°C or more 10 kΩ or higher

        If the result is not as specified, replace the front seat cushion heater assembly RH.

  4. INSPECT FRONT SEAT CUSHION HEATER ASSEMBLY RH (w/ Climate Control Seat System)

    A01X9R3E01
    Text in Illustration
    *1 Thermostat
    *2 Connector A
    *3 Connector B
    *a

    Component without harness connected

    (Front Seat Cushion Heater Assembly RH)


    1. Check the front seat cushion heater assembly RH.


      1. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Front Seat Cushion Heater Assembly RH
        Tester Connection Condition Specified Condition

        A1 - A3

        A1 - B1

        A3 - B2

        B1 - B2

        Seat cushion heater temperature 25°C (77°F) 2.5 to 3.0 Ω
        A2 - A3 8 to 12 kΩ
      2. Heat the thermostat with a light.

      3. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Thermostat
        Tester Connection Condition Specified Condition

        A1 - A3

        A1 - B1

        A1 - B2

        46 to 54°C or more 10 kΩ or higher