THEFT DETERRENT SYSTEM(w/ Entry and Start System) Glass Breakage Sensor Circuit

DESCRIPTION

When the glass breakage sensor detects that the back door glass, quarter window glass LH or quarter window glass RH is tapped or broken, the sensor will set off the alarm for 30 seconds.

WIRING DIAGRAM

A01WZSBE04

CAUTION / NOTICE / HINT


PROCEDURE


  1. READ VALUE USING TECHSTREAM (GLASS BREAK SENSOR)


    1. Connect the GTS to the DLC3.

    2. Turn the power switch on (IG).

    3. Turn the Techstream on.

    4. Enter the following menus: Body Electrical / Main Body / Data List.

    5. According to the display on the GTS, read the Data List.

      Main Body
      Tester Display Measurement Item/Range Normal Condition Diagnostic Note
      Glass break sensor detection Glass breakage sensor detection / With or Without1

      With: Glass breakage sensor connected

      Without: Glass breakage sensor not connected

      -
      OK
      "With" (glass breakage sensor operating) appears on Techstream screen.
      Result
      Result Proceed to
      OK A
      NG (for LHD) B
      NG (for RHD) C

    A
    B
    C
  2. CHECK HARNESS AND CONNECTOR MAIN BODY ECU [MULTIPLEX NETWORK BODY ECU] - GLASS BREAKAGE SENSOR AND BODY GROUND


    1. Disconnect the E118 main body ECU (multiplex network body ECU) connector.

    2. Disconnect the S37 back door glass (glass breakage sensor) connector.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      E118-7 (GPBS) - S37-1 (SSR+) Always Below 1 Ω
      E118-7 (GPBS) - Body ground Always 10 kΩ or higher
      S37-1 (SSR+) - Body ground Always 10 kΩ or higher

    NG
    OK
  3. INSPECT BACK DOOR GLASS


    1. A01X0IWE01

      Disconnect the S37 sensor connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      S37-1 (SSR+) - S18-1 (E) Always Below 1 Ω
      Result
      Result Proceed to
      OK (for LHD) A
      OK (for RHD) B
      NG C

    A
    B
    C