ACTIVE HEIGHT CONTROL PUMP AND MOTOR REASSEMBLY

PROCEDURE


  1. INSTALL NO. 1 HEIGHT CONTROL BOLT CUSHION


    1. Install the 3 bolt cushions and 3 bolt holders to the pump and motor.

  2. INSTALL HEIGHT CONTROL RESERVOIR ASSEMBLY


    1. A01XA1M

      Using a 5 mm hexagon wrench, install the reservoir with the 5 bolts.

      Torque:
      5.5 N*m  { 56 kgf*cm, 49 in.*lbf }
  3. INSTALL HEIGHT CONTROL COMPRESSOR BRACKET ASSEMBLY


    1. A01X9LY

      Install the bracket with the 3 nuts.

      Torque:
      5.5 N*m  { 56 kgf*cm, 49 in.*lbf }
  4. CONNECT NO. 4 FRAME WIRE


    1. A01X4X7

      Connect the 2 connectors, clamp and frame wire.

  5. INSTALL HEIGHT CONTROL CAP TO RESERVOIR HOSE


    1. A01X63P

      Install the hose to the reservoir tank, and push the connector up to attach it.

    2. A01WZC1E01
      *1 Breather Plug

      Install the hose, 2 breather plugs and 3 clips to the reservoir hose.

  6. INSTALL HEIGHT CONTROL HOSE ASSEMBLY


    1. A01X6UUE03
      *1 Clamp
      *2 Clip
      *3 Height Control Hose

      Install the hose to the reservoir and motor with the 2 clips.

    2. Connect the clamp to the reservoir.

    3. A01WZDGE04
      *1 Clamp direction

      Check that the direction of the hose clamp is as shown in the illustration.