COMBINATION SWITCH INSPECTION

PROCEDURE


  1. INSPECT INTEGRATION CONTROL AND PANEL ASSEMBLY (w/o Active Height Control)


    1. B001YZQE30
      Text in Illustration
      *a

      Component without harness connected

      (Integration Control and Panel Assembly)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      5 (E) - 6 (P)

      Mode switch

      (ECT PWR) on

      Below 1 Ω

      Release mode switch

      (ECT PWR) off

      10 kΩ or higher
      5 (E) - 8 (2nd)

      Mode switch being pushed and held

      (ECT 2nd)

      Below 1 Ω

      Mode switch not pushed

      (ECT 2nd)

      10 kΩ or higher

      If the result is not as specified, replace the integration control and panel assembly.

  2. INSPECT INTEGRATION CONTROL AND PANEL ASSEMBLY (w/ Active Height Control)


    1. A01X2PME31
      Text in Illustration
      *a

      Component without harness connected

      (Integration Control and Panel Assembly)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      5 (E) - 6 (P)

      Mode switch being pushed and held

      (SPORTS S/S+)

      Below 1 Ω

      Mode switch not pushed

      (SPORTS S/S+)

      10 kΩ or higher
      5 (E) - 2 (B)

      Mode switch being pushed and held

      (NORMAL)

      Below 1 Ω

      Mode switch not pushed

      (NORMAL)

      10 kΩ or higher
      5 (E) - 3 (ECU)

      Mode switch being pushed and held

      (COMF/ECO)

      Below 1 Ω

      Mode switch not pushed

      (COMF/ECO)

      10 kΩ or higher

      If the result is not as specified, replace the integration control and panel assembly.