COMBINATION SWITCH INSPECTION

PROCEDURE


  1. INSPECT INTEGRATION CONTROL AND PANEL ASSEMBLY


    1. B001YZQE01
      Text in Illustration
      *a

      Component without harness connected

      (Integration Control and Panel Assembly)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      5 (E) - 6 (P)

      Mode switch

      (ECT PWR) on

      Below 1 Ω

      Release mode switch

      (ECT PWR) off

      10 kΩ or higher
      5 (E) - 8 (2nd)

      Mode switch being pushed and held

      (ECT 2nd)

      Below 1 Ω

      Mode switch not pushed

      (ECT 2nd)

      10 kΩ or higher

      If the result is not as specified, replace the integration control and panel assembly.