AUTOMATIC TRANSMISSION SYSTEM(for 1UR-FE), Diagnostic DTC:P2716

DTC Code DTC Name
P2716 Pressure Control Solenoid "D" Electrical (Shift Solenoid Valve SLT)

DESCRIPTION

A01X7VXE01

Shift solenoid valve SLT controls the transmission line pressure for smooth transmission operation based on signals from the throttle position sensor and vehicle speed sensor. The ECM adjusts the current to shift solenoid valve SLT to control the hydraulic line pressure coming from the primary regulator valve.

Appropriate line pressure assures smooth shifting with varying engine outputs.

DTC Code DTC Detection Condition Trouble Area
P2716 Open or short is detected in shift solenoid valve SLT circuit for 1 second or more while driving (1 trip detection logic)
  • Open or short in shift solenoid valve SLT circuit

  • Shift solenoid valve SLT

  • ECM

MONITOR DESCRIPTION

When an open or short in the shift solenoid valve SLT circuit is detected, the ECM interprets this as a fault. The ECM will turn on the MIL and store the DTC.

WIRING DIAGRAM

A01X7JJE42

PROCEDURE


  1. INSPECT NO. 1 TRANSMISSION WIRE (SHIFT SOLENOID VALVE SLT)


    1. A01XAP4E38
      Text in Illustration
      *a

      Component without harness connected

      (No. 1 Transmission Wire)

      Disconnect the No. 1 transmission wire connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      13 (SLT+) - 5 (SLT-) 20°C (68°F) 5.0 to 5.6 Ω
      13 (SLT+) - Body ground Always 10 kΩ or higher
      5 (SLT-) - Body ground Always 10 kΩ or higher

    NG
    OK
  2. CHECK HARNESS AND CONNECTOR (NO. 1 TRANSMISSION WIRE - ECM)

    A01X13EE02
    Text in Illustration
    *1 for LHD
    *2 for RHD
    *a

    Front view of wire harness connector

    (to ECM)


    1. Disconnect the ECM connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      for LHD
      Tester Connection Condition Specified Condition
      C45-9 (SLT+) - C45-8 (SLT-) 20°C (68°F) 5.0 to 5.6 Ω
      C45-9 (SLT+) - Body ground Always 10 kΩ or higher
      C45-8 (SLT-) - Body ground Always 10 kΩ or higher
      for RHD
      Tester Connection Condition Specified Condition
      C46-9 (SLT+) - C46-8 (SLT-) 20°C (68°F) 5.0 to 5.6 Ω
      C46-9 (SLT+) - Body ground Always 10 kΩ or higher
      C46-8 (SLT-) - Body ground Always 10 kΩ or higher

    OK
    NG
  3. INSPECT SHIFT SOLENOID VALVE SLT


    1. B00201YE02
      Text in Illustration
      *a

      Component without harness connected

      (Shift Solenoid Valve SLT)

      Remove shift solenoid valve SLT.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 2 20°C (68°F) 5.0 to 5.6 Ω
    3. Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

      OK
      Measurement Condition Specified Condition

      • Battery positive (+) with a 21 W bulb → Terminal 2

      • Battery negative (-) → Terminal 1

      Valve moves and makes an operating noise

    OK
    NG