CAN COMMUNICATION SYSTEM(for LHD) ECM Communication Stop Mode

DESCRIPTION

Detection Item Symptom Trouble Area
ECM Communication Stop Mode

Either condition is met:


  • "ECM (Engine)" is not displayed on the "Bus Check" screen.

  • "ECM Communication Stop Mode" in "DTC Communication Table" applies.


  • Power source or inside of ECM

  • ECM

WIRING DIAGRAM

A01X5UJE01
except 1VD-FTV
*a EFI MAIN
*b from Battery
*c from EFI Relay
*d to EFI Relay
A01X7E9E01
for 1VD-FTV
*a EFI MAIN
*b from Battery
*c from EFI Relay
*d to EFI Relay

CAUTION / NOTICE / HINT

Note

Inspect the fuses for circuits related to this system before performing the following inspection procedure.

PROCEDURE


  1. CHECK HARNESS AND CONNECTOR (ECM - BATTERY AND BODY GROUND)


    1. Disconnect the A38 and C45 ECM connectors.

      A01X34ZE01
      Text in Illustration
      *A except 1VD-FTV *B for 1VD-FTV
      *a

      Front view of wire harness connector

      (to ECM)

      - -
    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      except 1VD-FTV
      Tester Connection Condition Specified Condition
      C45-81 (E1) - Body ground Always Below 1 Ω
      C45-42 (E02) - Body ground Always Below 1 Ω
      C45-43 (E01) - Body ground Always Below 1 Ω
      C45-82 (ME01) - Body ground Always Below 1 Ω
      for 1VD-FTV
      Tester Connection Condition Specified Condition
      C45-81 (E1) - Body ground Always Below 1 Ω
      C45-21 (E02) - Body ground Always Below 1 Ω
      C45-22 (E01) - Body ground Always Below 1 Ω
    3. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      except 1VD-FTV
      Tester Connection Condition Specified Condition
      A38-1 (BATT) - Body ground Always 11 to 14 V
      A38-2 (+B2) - Body ground Battery positive (+) voltage applied to terminal A38-34 (MREL) 11 to 14 V
      A38-3 (+B) - Body ground Battery positive (+) voltage applied to terminal A38-34 (MREL) 11 to 14 V
      for 1VD-FTV
      Tester Connection Condition Specified Condition
      A38-20 (BATT) - Body ground Always 11 to 14 V
      A38-2 (+B) - Body ground Battery positive (+) voltage applied to terminal A38-44 (MREL) 11 to 14 V
      Result
      Result Proceed to
      OK (for 1GR-FE) A
      OK (for 1UZ-FE) B
      OK (for 3UR-FE) C
      OK (for 1VD-FTV) D
      NG E

    A
    B
    C
    D
    E