GENERATOR INSPECTION

PROCEDURE


  1. INSPECT GENERATOR ROTOR ASSEMBLY


    1. Check the resistance.


      1. A01X3JDE02
        Text in Illustration
        *1 Slip Ring

        Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        Slip ring - Slip ring 20°C (68°F) 1.5 to 1.9 Ω

        If the result is not as specified, replace the generator rotor assembly.

      2. A01XA3UE01
        Text in Illustration
        *1 Slip Ring
        *2 Rotor Core

        Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        Slip ring - Rotor core Always 10 kΩ or higher

        If the result is not as specified, replace the generator rotor assembly.

    2. A01X2INE03
      Text in Illustration
      *1 Diameter

      Using a vernier caliper, measure the slip ring diameter.

      Standard diameter
      14.2 to 14.8 mm (0.559 to 0.583 in.)
      Minimum diameter
      14.0 mm (0.551 in.)

      If the diameter is less than the minimum, replace the generator rotor assembly.

    3. A01X1KF

      Check that the generator rotor bearing is not rough or worn.

      If necessary, replace the generator rotor assembly.

  2. INSPECT GENERATOR BRUSH HOLDER ASSEMBLY


    1. A01X7ZUE06
      Text in Illustration
      *1 Length

      Using a vernier caliper, measure the brush length.

      Standard exposed length
      9.5 to 11.5 mm (0.374 to 0.453 in.)
      Minimum exposed length
      4.5 mm (0.177 in.)

      If the brush length is less than the minimum, replace the generator brush holder assembly.