MASS AIR FLOW METER(w/o DPF) INSPECTION

PROCEDURE


  1. INSPECT MASS AIR FLOW METER


    1. Check the output voltage.


      1. A01X7RBE06
        *a Component without harness connected: (MAF Meter)
        *b Air

        Apply battery voltage across terminals 1 (+B) and 2 (E2G).

        Note

        While using the battery during inspection, do not bring the positive and negative tester probes too close to each other as a short circuit may occur.

      2. Using a voltmeter, connect the positive (+) tester probe to terminal 3 (VG), and negative (-) tester probe to terminal 2 (E2G).

      3. Blow air into the MAF meter, and check that the voltage fluctuates.

        If the result is not as specified, replace the MAF meter.

    2. A01X0LSE01
      *1 Platinum Hot Wire (Heater)

      Perform a visual check for any foreign matter on the platinum hot wire (heater) of the mass air flow meter shown in the illustration.

      OK
      There is no foreign material.

      If the result is not as specified, replace the mass air flow meter.

    3. Check the IAT sensor.

      A01X34WE01

      1. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        4 (THA) - 5 (E2) -20°C (-4°F) 12.5 to 16.9 kΩ
        20°C (68°F) 2.19 to 2.67 kΩ
        60°C (140°F) 0.5 to 0.68 kΩ

        If the result is not as specified, replace the MAF meter.