DESCRIPTION
When the engine switch is turned on (IG), battery voltage is applied to the IGSW of the ECM. The output signal from the MREL terminal of the ECM causes a current to flow to the coil, closing the contacts of the integration relay (EFI) and supplying power to either terminal +B or +B2 of the ECM.
WIRING DIAGRAM
CAUTION / NOTICE / HINT
Note
Inspect the fuses for circuits related to this system before performing the following inspection procedure.
PROCEDURE
INSPECT INTEGRATION RELAY (INTEGRATION RELAY - BODY GROUND)
| *a | Front view of wire harness connector: (to Integration Relay) |
Remove the integration relay from the engine room relay block.
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | ||||||
|---|---|---|---|---|---|---|
|
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
INSPECT INTEGRATION RELAY (EFI AND IG2 RELAY)
| *1 | Component without harness connected: (Integration Relay) |
Remove the integration relay from the engine room relay block.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
| NG |
|
REPLACE INTEGRATION RELAY |
| OK |
|
CHECK HARNESS AND CONNECTOR (+B, +B2 AND MREL CIRCUIT)
| *a | Front view of wire harness connector: (to Integration Relay) |
| *b | Front view of wire harness connector: (to ECM) |
Check the harness and the connectors between the integration relay and the ECM.
Remove the integration relay from the engine room relay block.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Check the harness and connectors between the integration relay and body ground.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
CHECK HARNESS AND CONNECTOR (ECM - BODY GROUND)
| *1 | Front view of wire harness connector: (to ECM) |
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
INSPECT ECM (IGSW VOLTAGE)
| *1 | Front view of wire harness connector: (to ECM) |
Disconnect the ECM connectors.
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | ||||||
|---|---|---|---|---|---|---|
|
| OK |
|
REPLACE ECM Click here |
| NG |
|
CHECK HARNESS AND CONNECTOR (INTEGRATION RELAY - ECM, INTEGRATION RELAY - BODY GROUND)
| *1 | Front view of wire harness connector: (to Integration Relay) |
| *2 | Front view of wire harness connector: (to ECM) |
Remove the integration relay from the engine room relay block.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
CHECK HARNESS AND CONNECTOR (MAIN BODY ECU - ENGINE ROOM RELAY BLOCK)
| *1 | Front view of wire harness connector: (to Main Body ECU) |
| *2 | Front view of wire harness connector: (to Integration Relay) |
Remove the integration relay from the engine room relay block.
Disconnect the E2 main body ECU connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
CHECK ENTRY AND START SYSTEM (POWER SOURCE MODE DOES NOT CHANGE)
Check the entry and start system Click here.
| OK |
|
REPLACE ECM Click here |
| NG |
|
REPAIR ENTRY AND START SYSTEM |