IGNITION COIL AND SPARK PLUG REMOVAL

PROCEDURE


  1. REMOVE V-BANK COVER

    Click here

  2. REMOVE AIR CLEANER CAP AND HOSE


    1. Remove the air cleaner cap and hose.


      1. B001VZE

        Disconnect the mass air flow meter connector, vacuum hose and No. 2 PCV hose and detach the clamp.

      2. Loosen the clamp.

      3. Unfasten the 4 hook clamps, and then remove the bolt and the air cleaner cap and hose.

  3. REMOVE AIR CLEANER CASE SUB-ASSEMBLY

    Click here

  4. REMOVE AIR TUBE (w/ Secondary Air Injection System)

    Click here

  5. REMOVE NO. 1 EMISSION CONTROL VALVE SET (w/ Secondary Air Injection System)

    Click here

  6. REMOVE NO. 2 AIR TUBE (w/ Secondary Air Injection System)

    Click here

  7. REMOVE NO. 2 EMISSION CONTROL VALVE SET (w/ Secondary Air Injection System)

    Click here

  8. REMOVE IGNITION COIL ASSEMBLY


    1. B001ZIWE02
      Text in Illustration
      *A Bank 1
      *B Bank 2

      Disconnect the 6 ignition coil connectors.

    2. Remove the 6 bolts and 6 ignition coils.

  9. REMOVE SPARK PLUG


    1. Remove the 6 spark plugs.