SFI SYSTEM, Diagnostic DTC:P144C, P144D

DTC Code DTC Name
P144C Open in Secondary Air Injection System Heater Control Circuit
P144D Short in Secondary Air Injection System Heater Control Circuit

DESCRIPTION

The ECM operates the air pump heater relay which causes the air pump heater to operate.

DTC No. DTC Detection Condition Trouble Area
P144C Open or short in the air pump heater relay circuit for 5 seconds (1 trip detection logic).
  • Open or short in air pump heater relay circuit

  • Air pump heater relay

  • ECM

P144D Open or short in the air pump heater relay circuit for 5 seconds (1 trip detection logic).
  • Open or short in air pump heater relay circuit

  • Air pump heater relay

  • ECM

WIRING DIAGRAM

Refer to DTC P0412 Click here.

CAUTION / NOTICE / HINT

Note

Inspect the fuses of circuits related to this system before performing the following inspection procedure.

Tech Tips

Read freeze frame data using the GTS. Freeze frame data records the engine condition when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air-fuel ratio was lean or rich, and other data from the time the malfunction occurred.

PROCEDURE


  1. INSPECT AIR PUMP HEATER RELAY (AIR PMP HTR)


    1. Inspect the integration relay (AIR PMP HTR) Click here.


    NG
    OK
  2. CHECK AIR PUMP HEATER RELAY (POWER SOURCE)


    1. Remove the integration relay (AIR PMP HTR).

    2. B001ZLJE05
      Text in Illustration
      *a Front view of wire harness connector (to Integration Relay)

      Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Condition Specified Condition
      1X-1 - Body ground Always 11 to 14 V
    3. Reinstall the integration relay (AIR PMP HTR).


    NG
    OK
  3. CHECK HARNESS AND CONNECTOR (ECM - AIR PUMP HEATER RELAY (AI-PMP HTR))


    1. Remove the integration relay (AIR PMP HTR).

    2. Disconnect the ECM connector.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance (Check for Open)
      Tester Connection Condition Specified Condition
      1P-10 - A38-14 (HAI1) Always Below 1 Ω
      Standard Resistance (Check for Short)
      Tester Connection Condition Specified Condition
      1P-10 or A38-14 (HAI1) - Body ground Always 10 kΩ or higher
    4. Reinstall the integration relay (AIR PMP HTR).

    5. Reconnect the ECM connector.


    OK
    NG