| Fluid level rise (Maximum) | 5.0 mm (0.197 in.) | |
| Fluid pressure at idle speed with valve closed | except Middle East | 10000 to 10700 kPa (102 to 109 kgf/cm2, 1450 to 1551 psi) |
| for Middle East | 12200 to 13200 kPa (125 to 134 kgf/cm2, 1769 to 1914 psi) | |
| Fluid pressure at idle speed with valve fully open and turn the steering wheel to the full lock position | except Middle East | 10000 to 10700 kPa (102.0 to 109.0 kgf/cm2, 1450 to 1551 psi) |
| for Middle East | 12200 to 13200 kPa (125 to 134 kgf/cm2, 1769 to 1914 psi) | |
| Fluid level rise (Maximum) | 5.0 mm (0.197 in.) | ||
| Fluid pressure at idle speed with valve closed | w/o Variable Flow Control Solenoid Valve | except Middle East | 10000 to 10700 kPa (102 to 109 kgf/cm2, 1450 to 1551 psi) |
| for Middle East | 12200 to 13200 kPa (125 to 134 kgf/cm2, 1769 to 1914 psi) | ||
| w/ Variable Flow Control Solenoid Valve | except Middle East | 10000 to 10700 kPa (102 to 109 kgf/cm2, 1450 to 1551 psi) | |
| for Middle East | 11500 to 12500 kPa (118 to 127 kgf/cm2, 1668 to 1812 psi) | ||
| Fluid pressure at idle speed with valve fully open and turn the steering wheel to the full lock position | w/o Variable Flow Control Solenoid Valve | except Middle East | 10000 to 10700 kPa (102.0 to 109.0 kgf/cm2, 1450 to 1551 psi) |
| for Middle East | 12200 to 13200 kPa (125 to 134 kgf/cm2, 1769 to 1914 psi) | ||
| w/ Variable Flow Control Solenoid Valve | for Middle East | 10000 to 10700 kPa (102.0 to 109.0 kgf/cm2, 1450 to 1551 psi) |
|
| for Middle East | 11500 to 12500 kPa (118 to 127 kgf/cm2, 1668 to 1812 psi) | ||
| Fluid level rise (Maximum) | 5.0 mm (0.197 in.) | ||
| Fluid pressure at idle speed with valve closed | w/o Variable Flow Control Solenoid Valve | except Middle East | 10000 to 10700 kPa (102 to 109 kgf/cm2, 1450 to 1551 psi) |
| for Middle East | 12200 to 13200 kPa (125 to 134 kgf/cm2, 1769 to 1914 psi) | ||
| w/ Variable Flow Control Solenoid Valve | except Middle East | 10000 to 10700 kPa (102 to 109 kgf/cm2, 1450 to 1551 psi) | |
| for Middle East | 11500 to 12500 kPa (118 to 127 kgf/cm2, 1668 to 1812 psi) | ||
| Fluid pressure at idle speed with valve fully open and turn the steering wheel to the full lock position | w/o Variable Flow Control Solenoid Valve | except Middle East | 10000 to 10700 kPa (102.0 to 109.0 kgf/cm2, 1450 to 1551 psi) |
| for Middle East | 12200 to 13200 kPa (125 to 134 kgf/cm2, 1769 to 1914 psi) | ||
| w/ Variable Flow Control Solenoid Valve | for Middle East | 10000 to 10700 kPa (102.0 to 109.0 kgf/cm2, 1450 to 1551 psi) |
|
| for Middle East | 11500 to 12500 kPa (118 to 127 kgf/cm2, 1668 to 1812 psi) | ||
| Fluid level rise (Maximum) | 5.0 mm (0.197 in.) | ||
| Fluid pressure at idle speed with valve closed | w/o Variable Flow Control Solenoid Valve | except Middle East | 10000 to 10700 kPa (102 to 109 kgf/cm2, 1450 to 1551 psi) |
| for Middle East | 12200 to 13200 kPa (125 to 134 kgf/cm2, 1769 to 1914 psi) | ||
| w/ Variable Flow Control Solenoid Valve | except Middle East | 10000 to 10700 kPa (102 to 109 kgf/cm2, 1450 to 1551 psi) | |
| for Middle East | 11500 to 12500 kPa (118 to 127 kgf/cm2, 1668 to 1812 psi) | ||
| Fluid pressure at idle speed with valve fully open and turn the steering wheel to the full lock position | w/o Variable Flow Control Solenoid Valve | except Middle East | 10000 to 10700 kPa (102.0 to 109.0 kgf/cm2, 1450 to 1551 psi) |
| for Middle East | 12200 to 13200 kPa (125 to 134 kgf/cm2, 1769 to 1914 psi) | ||
| w/ Variable Flow Control Solenoid Valve | for Middle East | 10000 to 10700 kPa (102.0 to 109.0 kgf/cm2, 1450 to 1551 psi) |
|
| for Middle East | 11500 to 12500 kPa (118 to 127 kgf/cm2, 1668 to 1812 psi) | ||
| Vane pump shaft and vane pump housing oil clearance (Maximum) | except 1VD-FTV | 0.07 mm (0.00276 in.) |
| Vane pump shaft and vane pump housing oil clearance (Maximum) | for 1VD-FTV | 0.08 mm (0.00315 in.) |
| Vane plate thickness (Standard) | 1.405 to 1.411 mm (0.0553 to 0.0556 in.) | |
| Clearance between the vane pump rotor groove and vane pump plate (Maximum) | 0.03 mm (0.00118 in.) | |
| Compression spring free length (Minimum) | w/ Variable Flow Control Solenoid Valve | 31.3 mm (1.23 in.) |
| Vane pump rotating torque | 0.3 N*m (3 kgf*cm, 2 in.*lbf) or less | |