3UR-FE STARTING SERVICE DATA

Starter assembly No-load characteristics current 150 A or less at 11.5 V
Starter armature assembly Standard resistance Segment -Segment Below 1 Ω
Segment - Armature coil core 10 kΩ or higher
Maximum circle runout 0.05 mm (0.00197 in.)
Standard commutator diameter 29 mm (1.14 in.)
Minimum commutator diameter 28 mm (1.10 in.)
Standard undercut depth 0.4 mm (0.0157 in.)
Minimum undercut depth 0.2 mm (0.00787 in.)
Brush length Standard length 14.4 mm (0.567 in.)
Minimum length 9.0 mm (0.354 in.)
Brush spring Standard spring installed load 22 to 27 N (2 to 3 kgf, 5.0 to 6.1 lbf)
Minimum spring installed load 14 N (1 kgf, 3.1 lbf)
Magnet starter switch assembly Standard resistance Terminal 50 - Terminal C Below 1 Ω
Terminal 50 - Switch body Below 2 Ω
Starter relay Standard resistance 3 - 5 10 kΩ or higher (Battery voltage is not applied to terminals 1 and 2)
Below 1 Ω (Battery voltage is applied to terminals 1 and 2)
Starter cut relay Standard resistance 3 - 5 10 kΩ or higher (Battery voltage is not applied to terminals 1 and 2)
Below 1 Ω (Battery voltage is applied to terminals 1 and 2)
ACC relay (Main body ECU) Standard resistance 2A-1 - 2D-8 10 kΩ or higher (Battery voltage is not applied between 2D-45 and 2D- 62)
Below 1 Ω (Battery voltage is applied between 2D-45 and 2D- 62)
Engine switch Standard resistance 7 - 5 Below 1 Ω (Engine switch is pushed)
2 - 5 Below 1 Ω (Engine switch is pushed)
7 - 5 10 kΩ or higher (Engine switch is not pushed)
2 - 5 10 kΩ or higher (Engine switch is not pushed)