| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 4 (THA) - 5(E2) | -20°C (-4°F) | 12.5 to 16.9 kΩ |
| 20°C (68°F) | 2.19 to 2.67 kΩ | |
| 60°C (140°F) | 0.50 to 0.68 kΩ |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 - 2 | Hot | 835 to 1400Ω |
| Cold | 1060 to 1645Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 - 2 | Hot | 1630 to 2740Ω |
| Cold | 2065 to 3225Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 - 2 | Approximately. 20°C (68°F) | 2.32 to 2.59 kΩ |
| Approximately. 80°C (176°F) | 0.310 to 0.326 kΩ |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 - 2 | 20°C (68°F) | 1.8 to 3.4 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 - 2 | Approximately. 20°C (68°F) | 2.21 to 2.65 kΩ |
| Approximately. 60°C (140°F) | 0.55 to 0.61 kΩ |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| IG2 MAIN fuse | Always | Below 1 Ω |
| 1C-1 - 1B-8 | Battery voltage is not applied to terminals 1B-6 and 1B-7 | 10 kΩ or higher |
| Battery voltage is applied to terminals 1B- 6 and 1B-7 | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| EFI No. 1 fuse | Always | Below 1 Ω |
| 1C-1 - 1B-4 | Battery voltage is not applied to terminals 1B-2 and 1B-3) | 10 kΩ or higher |
| Battery voltage is applied to terminals 1B- 2 and 1B-3) | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| EFI No. 1 fuse | Always | Below 1 Ω |
| 1C-1 - 1A-4 | Battery voltage is not applied to terminals 1A-2 and 1A-3 | 10 kΩ or higher |
| Battery voltage is applied to terminals 1A-2 and 1A-3 | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - 5 | Battery voltage is not applied to terminals 1 and 2 | 10 kΩ or higher |
| Battery voltage is applied to terminals 1 and 2 | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - 5 | Battery voltage is not applied to terminals 1 and 2 | 10 kΩ or higher |
| Battery voltage is applied to terminals 1 and 2 | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - 5 | Battery voltage is not applied to terminals 1 and 2 | 10 kΩ or higher |
| Battery voltage is applied to terminals 1 and 2 | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - 5 | Battery voltage is not applied to terminals 1 and 2 | 10 kΩ or higher |
| Battery voltage is applied to terminals 1 and 2 | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 2A-1 - 2B-17 | Battery voltage is not applied to terminals 2B-5 and 2D-43 | 10 kΩ or higher |
| Battery voltage is applied to terminals 2B-5 and 2D-43 | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1-2 | 20 °C | 37 to 44 Ω |
| 1 - Body ground 2 - Body ground |
Always | 10 kΩ or higher |
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| C80-3 (VC) - C80-1 (E2) | Engine switch on (IG) | 4.5 to 5.5V |
| Tester Display | Condition | Specified Condition |
|---|---|---|
| Accel Sens. No.1 Volt % | Released | 10 to 22% |
| Depressed | 52 to 90% | |
| Accel Sens. No.2 Volt % | Released | 24 to 40% |
| Depressed | 68 to 99% |