PROCEDURE
INSTALL FRONT EXHAUST PIPE ASSEMBLY
Install a new gasket and the front exhaust pipe to the exhaust manifold RH with 2 new nuts.
Connect the heated oxygen sensor connector.
INSTALL HEATED OXYGEN SENSOR (for Bank 2 Sensor 2)
INSTALL FRONT NO. 2 EXHAUST PIPE ASSEMBLY
Install a new gasket and the front No. 2 exhaust pipe to the exhaust manifold LH with 2 new nuts.
| *1 | for Automatic Transmission: |
| *2 | Bracket |
| *3 | for Manual Transmission: |
Connect the heated oxygen sensor connector.
Tech Tips
Hook the wire harness to the bracket.
INSTALL CENTER EXHAUST PIPE ASSEMBLY
Check the free length.
Using a vernier caliper, measure the free length of the compression spring.
| Minimum free length |
|---|
| 43 mm (1.693 in.) |
If the free length is less than the minimum, replace the compression spring.
Connect the center exhaust pipe to the 3 exhaust pipe supports.
Install 2 new gaskets to the front exhaust pipe and front No. 2 exhaust pipe.
Install the center exhaust pipe with the 4 bolts and 2 compression springs.
INSTALL TAILPIPE ASSEMBLY
Install the tailpipe to the 2 exhaust pipe supports.
Set a new gasket to the center exhaust pipe.
| *1 | Upper |
| *2 | LH Side |
| *3 | Front |
| *4 | Gasket |
Connect the tailpipe to the center pipe with a new clamp.
Tech Tips
Install the clamp within the angle range shown in the illustration.
INSTALL HEATED OXYGEN SENSOR (for Bank 1 Sensor 2)
INSPECT FOR EXHAUST GAS LEAK