PROCEDURE
INSPECT CANISTER
| *1 | Port A |
| *2 | Port B |
| *3 | Port C |
|
Air |
Visually check the canister for cracks or damage.
Blow compressed air of 4.9 kPa (50 gf/cm2, 0.71 psi) into port A and check that air flows without resistance from port B and port C.
If the result is not as specified, replace the canister.
Apply a vacuum of 1.96 kPa (20 gf/cm2, 0.28 psi) to port A. Check that the vacuum does not decrease when ports B and C are closed, and check that air flows when port B is opened.
If the result is not as specified, replace the canister.
CLEAN FILTER IN CANISTER
| *1 | Port A |
| *2 | Port B |
|
Air |
Clean the filter by blowing compressed air of 4.9 kPa (50 gf/cm2, 0.71 psi) into port A while holding port B closed.
Note
Do not attempt to wash the canister.