CANISTER INSPECTION

PROCEDURE


  1. INSPECT CHARCOAL CANISTER


    1. B0010T9E04
      Text in Illustration
      *1 Port A
      *2 Port B
      *3 Port C
      B001XPG Air

      Visually check the canister for cracks or damage.

    2. Blow compressed air at 5 kPa (0.05 kgf/cm2, 0.7 psi) into port A and check that air flows without resistance from port B and port C.

      If the result is not as specified, replace the canister.

    3. Apply a vacuum of 2 kPa (0.02 kgf/cm2, 0.3 psi) to port A. Check that the vacuum does not decrease when ports B and C are closed, and check that air flows when port B is opened.

      If the result is not as specified, replace the canister.

  2. CLEAN FILTER IN CANISTER


    1. B0010W1E04
      Text in Illustration
      *1 Port A
      *2 Port B
      B001XPG Air

      Clean the filter by blowing compressed air at 5 kPa (0.05 kgf/cm2, 0.7 psi) into port A while holding port B closed.

      Note

      Do not attempt to wash the canister.