AIR SWITCHING VALVE(for Bank 2) INSPECTION

PROCEDURE


  1. INSPECT AIR SWITCHING VALVE ASSEMBLY


    1. A01X737E03
      Text in Illustration
      *a

      Component without harness connected

      (Air Switching Valve)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 5 20°C (68°F) 4.5 to 5.5 Ω
      1 - Body ground Always 1 MΩ or higher
      5 - Body ground

      Note

      When measuring the resistance, do not touch terminals 2, 3 or 4.

      Tech Tips

      When measuring the resistance, make sure that the surface temperature of the air switching valve assembly is 20°C (68°F).

      If the result is not as specified, replace the air switching valve assembly.

    2. A01X2I6E04
      Text in Illustration
      *1 Port A
      *2 Port B
      B001XPG Air

      Check the operation of the air switching valve.


      1. Check that air does not flow from port A to port B.

        Note

        Make sure the applied pressure is 30 kPa (0.3 kgf/cm2, 4.4 psi) or less.

        If the result is not as specified, replace the air switching valve assembly.

      2. A01X4HFE01
        Text in Illustration
        *1 Port A
        *2 Port B
        *a

        Component without harness connected

        (Air Switching Valve)

        B001XPG Air

        Apply battery voltage across terminals 1 and 5.

        Note

        When applying voltage, do not touch terminals 2, 3 or 4.

      3. Check that air flows from port A to port B.

        If the result is not as specified, replace the air switching valve assembly.