AIR SWITCHING VALVE(for Bank 1) REMOVAL

PROCEDURE


  1. REMOVE V-BANK COVER SUB-ASSEMBLY

    Click here

  2. DISCONNECT NO. 2 AIR INJECTION SYSTEM HOSE


    1. A01X3NL

      Disconnect the connector.

    2. Disconnect the No. 2 air injection system hose.

  3. REMOVE AIR SWITCHING VALVE ASSEMBLY


    1. A01XA0U

      Remove the bolt and then disconnect the wire harness clamp bracket.

    2. A01X7LO

      Remove the 2 bolts.

    3. A01X5KE

      Remove the 3 bolts, air switching valve and gasket.

      Note

      Be careful not to damage the installation surface of the gasket.