HUMIDITY SENSOR REMOVAL

PROCEDURE


  1. REMOVE PROTECTOR


    1. B001MYM

      Disengage the 2 guides and slide the protector as shown in the illustration.

    2. Disengage the 2 claws and remove the protector.

  2. REMOVE HUMIDITY SENSOR


    1. B001LQX

      Disconnect the connector.

    2. A004XO0E02
      Text in Illustration
      *1 Stopper

      Release the stopper by pulling it down.

    3. Remove the humidity sensor as shown in the illustration.