CONDENSER REASSEMBLY

PROCEDURE


  1. INSTALL COOLER DRYER


    1. B001LTS

      Using pliers, install a new cooler dryer to the modulator.

    2. for Type A:


      1. B001MNN

        Apply a sufficient amount of compressor oil to the O-ring and the fitting surfaces of a new cap.

        Compressor oil
        ND-OIL 11 or equivalent
    3. for Type B:


      1. B001MTH

        Apply a sufficient amount of compressor oil to the 3 O-rings and the fitting surfaces of a new cap.

        Compressor oil
        ND-OIL 11 or equivalent
    4. B001MZSE02
      Text in Illustration
      *1 14 mm Straight Hexagon Wrench

      Using a 14 mm straight hexagon wrench, install the cap to the cooler condenser core.

      Torque:
      for Type A
      2.9 N*m  { 30 kgf*cm, 26 in.*lbf }
      for Type B
      4.0 N*m  { 41 kgf*cm, 35 in.*lbf }

      Note


      • Keep the O-ring and O-ring fitting surfaces clean from dirt or any foreign matter.

      • Do not use any compressor oil other than ND-OIL 11 or equivalent. If any compressor oil other than ND-OIL 11 or equivalent is used, compressor motor insulation performance may decrease, resulting in a leakage of electric power.

  2. INSTALL COOLER CONDENSER CUSHION


    1. for LH Side:


      1. B001M0Y

        Install the cooler condenser cushion.

    2. for RH Side:


      1. B001LAE

        Install the cooler condenser cushion.