DESCRIPTION
This circuit is the power source circuit for the meter. This circuit provides two types of power sources; one is a constant power source, and the other is an IG power source. If a voltage of 12 V is not applied to terminal IG2 when the power switch is turned on (IG), the indicators will not operate.
WIRING DIAGRAM
| *1 | from MAIN Fuse |
| *2 | from IG2 Relay |
| *3 | Combination Meter Assembly |
PROCEDURE
CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY CIRCUIT)
| *a | Front view of wire harness connector (to Combination Meter Assembly) |
Disconnect the H19 connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
| OK |
|
REPLACE COMBINATION METER ASSEMBLY Click here |
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |