PROCEDURE
INSTALL MAIN BODY ECU (for LHD)
Note
Make sure that no foreign matter gets on the connecting surfaces.
Do not touch the ECU connector.
| *1 | Housing Sidewall |
| *a | 20° |
Insert the main body ECU up to the position it contacts the housing sidewall of the guide as shown in the illustration.
Tech Tips
Make sure to keep the angle 20° or more as shown in the illustration.
| *1 | Housing Sidewall |
| *2 | Junction Block Fuse |
Slide the guide of the main body ECU along the housing sidewall so that it contacts the junction block fuses as shown in the illustration.
| *1 | Side A Contact Portion |
While contacting the main body ECU to side A of the junction block (axis of rotation), rotate it downward as shown in the illustration.
| *1 | Push Area |
Press the push area until the claw engages to install the main body ECU.
Note
Make sure to press only the push area.
Confirm the engagement of the main body ECU and junction block by listening for the lock sound.
Tech Tips
If a lock sound cannot be heard, visually check the lock part engagement. The engagement can also be confirmed if the main body ECU and junction block are flush.
INSTALL MAIN BODY ECU (for RHD)
Note
Make sure that no foreign matter get on the connecting surfaces.
Do not touch the ECU connector.
| *1 | Housing Sidewall |
| *a | 20° |
Insert the main body ECU up to the position it contacts the housing sidewall of the guide as shown in the illustration.
Tech Tips
Make sure to keep the angle 20° or more as shown in the illustration.
| *1 | Housing Sidewall |
| *2 | Junction Block Fuse |
Slide the guide of the main body ECU along the housing sidewall so that it contacts the junction block fuses as shown in the illustration.
| *1 | Side A Contact Portion |
While contacting the main body ECU to side A of the junction block (point of rotation), rotate it downward as shown in the illustration.
| *1 | Push Area |
Press the push area until the claw engages to install the main body ECU.
Note
Make sure to press only the push area.
Confirm the engagement of the main body ECU and junction block by listening for the lock sound.
Tech Tips
If a lock sound cannot be heard, visually check the lock part engagement. The engagement can also be confirmed if the main body ECU and junction block are flush.
INSTALL INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY (for LHD)
Engage the claw to install the connector as shown in the illustration.
Note
Be sure to engage the connector securely.
Engage the claw to lock the connector lock as shown in the illustration.
Engage the claw to connect the connector as shown in the illustration.
Note
Be sure to engage the connector securely.
Engage the 2 clamps to connect the wire harness.
Install the instrument panel junction block assembly with the bolt and nut.
Connect each connector.
Note
Be sure to engage each connector securely.
INSTALL INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY (for RHD)
Engage the claw to install the connector as shown in the illustration.
Note
Be sure to engage the connector securely.
Engage the claw to lock the connector lock as shown in the illustration.
Engage the claw to connect the connector as shown in the illustration.
Note
Be sure to engage the connector securely.
Install the instrument panel junction block assembly with the bolt and nut.
Connect each connector.
Note
Be sure to engage each connector securely.
INSTALL ECU INTEGRATION BOX LH (for RHD)
INSTALL LOWER INSTRUMENT PANEL SUB-ASSEMBLY