PROCEDURE
REMOVE REAR BUMPER ASSEMBLY
REMOVE ULTRASONIC SENSOR WITH CLIP (for Corner Sensor)
Tech Tips
Use the same procedure for all ultrasonic sensor with clips.
Disconnect the connector and disengage the clamp.
Tech Tips
This illustration is for the LH side. The orientation for the RH side is the opposite of the LH side.
Disengage the 2 claws and remove the ultrasonic sensor with clip.
Tech Tips
This illustration is for the LH side. The orientation for the RH side is the opposite of the LH side.
REMOVE ULTRASONIC SENSOR CLIP (for Corner Sensor)
Tech Tips
Use the same procedure for all ultrasonic sensor clips.
| *a | Protective Tape |
Using a screwdriver with its tip wrapped with protective tape, disengage the claw and remove the ultrasonic sensor clip from the No. 1 ultrasonic sensor.
Tech Tips
This illustration is for the LH side. The orientation for the RH side is the opposite of the LH side.
REMOVE ULTRASONIC SENSOR WITH CLIP (for Back Sensor)
Tech Tips
Use the same procedure for all ultrasonic sensor with clips.
Disconnect the connector and disengage the clamp.
Disengage the 2 claws and remove the ultrasonic sensor with clip.
REMOVE ULTRASONIC SENSOR CLIP (for Back Sensor)
Tech Tips
Use the same procedure for all ultrasonic sensor clips.
| *a | Protective Tape |
Using a screwdriver, disengage the claw and remove the ultrasonic sensor clip from the No. 1 ultrasonic sensor.
Tech Tips
This illustration is for the LH side. The orientation for the RH side is the opposite of the LH side.
REMOVE NO. 1 ULTRASONIC SENSOR RETAINER
Tech Tips
Use the same procedure for all No. 1 ultrasonic sensor retainers.
Perform this step only when necessary.
Remove the No. 1 ultrasonic sensor retainer.
REMOVE NO. 1 ULTRASONIC SENSOR