PROCEDURE
INSPECT WATER INLET WITH THERMOSTAT SUB-ASSEMBLY
Immerse the water inlet with thermostat sub-assembly in water and then gradually heat the water.
Check the valve opening temperature of the water inlet with thermostat sub-assembly.
| Valve opening temperature |
|---|
| 80 to 84°C (176 to 183°F) |
Tech Tips
If the valve opening temperature is not as specified, replace the water inlet with thermostat sub-assembly.
| *A | Compression Spring Shape: Tapered |
| *B | Compression Spring Shape: Straight |
| *a | Valve Lift |
| *b | Compression Spring |
Check the valve lift.
| Standard Valve Lift | ||||||||
|---|---|---|---|---|---|---|---|---|
|
Tech Tips
If the valve lift is not as specified, replace the water inlet with thermostat sub-assembly.
Check that the valve is fully closed when the water inlet with thermostat sub-assembly is at low temperatures (below 77°C (171°F)).
Tech Tips
If it is not fully closed, replace the water inlet with thermostat sub-assembly.