PROCEDURE
INSPECT COOLING FAN MOTOR
| *A | with Outer Mounted Type Horns |
| *B | with Inner Mounted Type Horns |
There are 2 types of cooling fan motors. Identify the type of the cooling fan motor according to the position of the horns.
Disconnect the cooling fan motor connector.
| *a | Component without harness connected (Cooling Fan Motor) |
Check that the cooling fan motor operates smoothly when the auxiliary battery is connected to the cooling fan motor connector.
Measure the current while the cooling fan motor is operating.
| Standard Current | ||||||||
|---|---|---|---|---|---|---|---|---|
|
If the result is not as specified, replace the cooling fan motor.
Connect the cooling fan motor connector.
INSPECT NO. 2 COOLING FAN MOTOR
| *A | with Outer Mounted Type Horns |
| *B | with Inner Mounted Type Horns |
There are 2 types of No. 2 cooling fan motors. Identify the type of the No. 2 cooling fan motor according to the position of the horns.
Disconnect the No. 2 cooling fan motor connector.
| *a | Component without harness connected (No. 2 Cooling Fan Motor) |
Check that the No. 2 cooling fan motor operates smoothly when the auxiliary battery is connected to the No. 2 cooling fan motor connector.
Measure the current while the No. 2 cooling fan motor is operating.
| Standard Current | ||||||||
|---|---|---|---|---|---|---|---|---|
|
If the result is not as specified, replace the No. 2 cooling fan motor.
Connect the No. 2 cooling fan motor connector.