WATER PUMP WITH MOTOR INSTALLATION

PROCEDURE


  1. INSTALL INVERTER WATER PUMP ASSEMBLY


    1. Install the inverter water pump assembly and water pump bracket with the 3 bolts.

      Torque:
      6.1 N*m  { 62 kgf*cm, 54 in.*lbf }

      Note

      Do not hold the inverter water pump assembly by the connector terminals when removing or installing it.

    2. A004YWPE04
      Text in Illustration
      *a Front Side
      *b Matchmark (Green)
      *c Matchmark (White)

      Connect the 2 water hose and connector.

      Note


      • Make sure that the clip is positioned as shown in the illustration.

      • Make sure to align the matchmarks of the hoses with the ribs of the inverter water pump assembly.

  2. INSTALL INVERTER TRAY BRACKET (for 2ZR-FXE)

    Click here

  3. INSTALL INVERTER TRAY BRACKET (for 5ZR-FXE)

    Click here

  4. INSTALL INVERTER RESERVE TANK ASSEMBLY (for 2ZR-FXE)

    Click here

  5. INSTALL INVERTER RESERVE TANK ASSEMBLY (for 5ZR-FXE)

    Click here

  6. INSTALL INVERTER WITH CONVERTER ASSEMBLY

    Click here

  7. ADD COOLANT (for Inverter)

    Click here

  8. INSPECT FOR COOLANT LEAK (for Inverter)

    Click here

  9. INSTALL NO. 1 ENGINE UNDER COVER