PROCEDURE
INSTALL INVERTER WATER PUMP ASSEMBLY
Install the inverter water pump assembly and water pump bracket with the 3 bolts.
Note
Do not hold the inverter water pump assembly by the connector terminals when removing or installing it.
| *a | Front Side |
| *b | Matchmark (Green) |
| *c | Matchmark (White) |
Connect the 2 water hose and connector.
Note
Make sure that the clip is positioned as shown in the illustration.
Make sure to align the matchmarks of the hoses with the ribs of the inverter water pump assembly.
INSTALL INVERTER TRAY BRACKET (for 2ZR-FXE)
INSTALL INVERTER TRAY BRACKET (for 5ZR-FXE)
INSTALL INVERTER RESERVE TANK ASSEMBLY (for 2ZR-FXE)
INSTALL INVERTER RESERVE TANK ASSEMBLY (for 5ZR-FXE)
INSTALL INVERTER WITH CONVERTER ASSEMBLY
ADD COOLANT (for Inverter)
INSPECT FOR COOLANT LEAK (for Inverter)
INSTALL NO. 1 ENGINE UNDER COVER