HYBRID CONTROL SYSTEM, Diagnostic DTC:P3004-131

DTC Code DTC Name
P3004-131 Power Cable Malfunction

DESCRIPTION

Refer to the description for DTC P0AE6-225 Click here.

The power management control ECU monitors the high-voltage wiring between the HV battery and the inverter with converter assembly and detects the following malfunction.

DTC No. INF Code DTC Detection Condition Trouble Area
P3004 131 The inverter voltage does not rise during precharge (time from when SMRP turns on until when SMRG turns on).
  • Hybrid battery junction block assembly

  • Frame wire

  • Inverter with converter assembly

  • HV battery

  • Wire harness or connector

WIRING DIAGRAM


CAUTION / NOTICE / HINT

CAUTION:


  • Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

  • After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work Click here.

    Tech Tips

    Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.

Note

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work Click here.

PROCEDURE


  1. CHECK DTC OUTPUT (HYBRID CONTROL)


    1. Connect the intelligent tester to the DLC3.

    2. Turn the power switch on (IG).

    3. Enter the following menus: Powertrain / Hybrid Control / DTC.

    4. Check if DTCs are output.

      Result
      Result Proceed to
      P3004-131 only is output. A
      DTCs shown in Table 1 are output simultaneously. B
      DTCs shown in Table 2 are output simultaneously. C
      Table 1
      DTC No. Relevant Diagnosis
      P0A1A-151, 155, 156, 658, 659 Generator Control Module
      P0A1B-164, 193, 512, 661, 786 Drive Motor "A" Control Module
      P0A1D-148 Hybrid Powertrain Control Module
      P0A78-266, 267, 586 Drive Motor "A" Inverter Performance
      P0A94-442 DC / DC Converter Performance
      P0ADB-227 Hybrid Battery Positive Contactor Control Circuit Low
      P0ADC-226 Hybrid Battery Positive Contactor Control Circuit High
      P0ADF-229 Hybrid Battery Negative Contactor Control Circuit Low
      P0AE0-228 Hybrid Battery Negative Contactor Control Circuit High
      P0AE6-225 Hybrid Battery Precharge Contactor Control Circuit Low
      P0AE7-224 Hybrid Battery Precharge Contactor Control Circuit High
      P0C76-523 Hybrid Battery System Discharge Time Too Long
      P2511-149 ECM/PCM Power Relay Sensor Circuit Intermittent
      P3004-800, 801 Power Cable Malfunction
      P324E-788 MG-ECU Power Relay Intermittent Circuit
      U0110 (all INF codes)*1 Lost Communication with Drive Motor Control Module
      Table 2
      DTC No. Relevant Diagnosis
      P0A95-123 High Voltage Fuse
      P0ABF-123 Hybrid Battery Pack Current Sensor Circuit
      P0AC0-123 Hybrid Battery Pack Current Sensor Circuit Range / Performance
      P0AC1-123 Hybrid Battery Pack Current Sensor "A" Circuit Low
      P0AC2-123 Hybrid Battery Pack Current Sensor "A" Circuit High
      P0AFC-123 Hybrid Battery Pack Sensor Module
      P0B3D-123 Hybrid Battery Voltage Sensor "A" Circuit Low
      P0B42-123 Hybrid Battery Voltage Sensor "B" Circuit Low
      P0B47-123 Hybrid Battery Voltage Sensor "C" Circuit Low
      P0B4C-123 Hybrid Battery Voltage Sensor "D" Circuit Low
      P0B51-123 Hybrid Battery Voltage Sensor "E" Circuit Low
      P0B56-123 Hybrid Battery Voltage Sensor "F" Circuit Low
      P0B5B-123 Hybrid Battery Voltage Sensor "G" Circuit Low
      P0B60-123 Hybrid Battery Voltage Sensor "H" Circuit Low
      P0B65-123 Hybrid Battery Voltage Sensor "I" Circuit Low
      P0B6A-123 Hybrid Battery Voltage Sensor "J" Circuit Low
      P0B6F-123 Hybrid Battery Voltage Sensor "K" Circuit Low
      P0B74-123 Hybrid Battery Voltage Sensor "L" Circuit Low
      P0B79-123 Hybrid Battery Voltage Sensor "M" Circuit Low
      P0B7E-123 Hybrid Battery Voltage Sensor "N" Circuit Low
      P0B83-123 Hybrid Battery Voltage Sensor "O" Circuit Low
      P308A-123 Hybrid Battery Voltage Sensor All Circuits Low
      U029A-123 Lost Communication with Hybrid Battery Pack Sensor Module

      Tech Tips


      • *1: If any INF codes are output for this DTC, refer to the corresponding diagnostic procedure.

      • P3004-131 may be output due to a malfunction which causes the DTCs in the table above to be output. In this case, first troubleshoot the output DTCs in the table above. Then, perform a reproduction test to check that no DTCs are output.

    5. Turn the power switch off.


    B
    C
    A
  2. CHECK FREEZE FRAME DATA (HYBRID CONTROL)


    1. Connect the intelligent tester to the DLC3.

    2. Turn the power switch on (IG).

    3. Enter the following menus: Powertrain / Hybrid Control / DTC.

    4. Read the freeze frame data of DTC P3004-131.

      Result
      Result Proceed to

      Both of the following conditions are met:


      • Post-boost voltage (VH-Voltage after Boosting) is below 50 V.

      • Difference between HV battery voltage (Power Resource VB) and pre-boost voltage (VL-Voltage before Boosting) is 50 V or less.

      A
      Other than above B
    5. Turn the power switch off.


    A
    B
  3. CHECK CONNECTOR CONNECTION CONDITION (POWER MANAGEMENT CONTROL ECU CONNECTOR)


    1. Check the connections of the power management control ECU connectors.

      B001M45E01
      Text in Illustration
      *A for LHD *B for RHD
      OK
      The connectors are connected securely and there are no contact problems.

    NG
    OK
  4. CHECK FRAME WIRE (INVERTER WITH CONVERTER ASSEMBLY SIDE)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. B001LYD

      Remove the inverter cover from the inverter with converter assembly.

    3. B001LA2E02

      Check the connection between the frame wire S1 and the inverter with converter assembly.

      OK
      The connectors are connected securely and there are no contact problems.
    4. Install the inverter cover to the inverter with converter assembly.


    NG
    OK
  5. CHECK FRAME WIRE (HYBRID BATTERY JUNCTION BLOCK ASSEMBLY SIDE)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Remove the upper hybrid battery cover sub-assembly Click here.

    3. B001MDJE02

      Check the connection between the frame wire S4, S3 and the hybrid battery junction block assembly.

      Torque:
      9.0 N*m  { 92 kgf*cm, 80 in.*lbf }
    4. Check for arc marks on the terminals of the frame wire.

      Result
      Result Proceed to
      The terminals are connected securely and there are no contact problems. There are no arc marks. A
      The terminals are not connected securely and there is a contact problem. There are arc marks. B
      The terminals are not connected securely and there is a contact problem. There are no arc marks. C
      The terminals are connected securely and there are no contact problems. There are arc marks. B
    5. Install the upper hybrid battery cover sub-assembly Click here.


    B
    C
    A
  6. CHECK FRAME WIRE (INVERTER WITH CONVERTER - HYBRID BATTERY JUNCTION BLOCK)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. B001LYD

      Remove the inverter cover from the inverter with converter assembly.

    3. Remove the upper hybrid battery cover sub-assembly Click here.

    4. B001LA2E02

      Disconnect the frame wire S1 from the inverter with converter assembly.

    5. B001L5VE02
      Text in Illustration
      *1 Frame Wire (Hybrid Battery Junction Block Assembly Side)
      *a

      Front view of Frame Wire connector

      (to Inverter with Converter Assembly)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      S4-1 (CBI) - S1-2 (CBI) Power switch off Below 1 Ω
      S3-1 (CEI) - S1-1 (CEI) Power switch off Below 1 Ω
    6. Connect the frame wire from the inverter with converter assembly.

    7. Install the upper hybrid battery cover sub-assembly Click here.

    8. Install the inverter cover to the inverter with converter assembly.


    NG
    OK
  7. CHECK CONDITION OF MAIN BATTERY CABLE CONNECTION(S)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Remove the upper hybrid battery cover sub-assembly Click here.

    3. B001KPZE02

      Check the connections between the main battery cables f2, h2 and the hybrid battery junction block assembly.

      OK
      The connectors are connected securely and not damaged.
    4. Check for arc marks on the terminals of the main battery cable connectors.

      Result
      Result Proceed to
      The terminals are connected securely and there are no contact problems. There are no arc marks. A
      The terminals are not connected securely and there is a contact problem. There are arc marks. B
      The terminals are not connected securely and there is a contact problem. There are no arc marks. C
      The terminals are connected securely and there are no contact problems. There are arc marks. B
    5. Install the upper hybrid battery cover sub-assembly Click here.


    B
    C
    A
  8. CHECK HV BATTERY

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Remove the upper hybrid battery cover sub-assembly Click here.

    3. B001LVQE02

      Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Switch Condition Specified Condition
      f2-1 (+) - 2 Power switch off 114 to 190 V
      h2-1 (-) - 1 Power switch off 54 to 90 V

      CAUTION:

      Do not allow the probes of the electrical tester to contact each other during this inspection.

    4. Install the upper hybrid battery cover sub-assembly Click here.


    NG
    OK
  9. CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - HYBRID BATTERY JUNCTION BLOCK)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Disconnect connector H3 from the power management control ECU.

    3. Remove the upper hybrid battery cover sub-assembly Click here.

    4. Disconnect the connector i3 that drives the relay of the hybrid battery junction block assembly.

      Tech Tips

      Before disconnecting the connector i3 that drives the relay of the hybrid battery junction block assembly, make sure that the connector is securely engaged.

    5. Measure the resistance according to the value(s) in the table below.

      B001M3ME04
      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      H3-4 (SMRB) - i3-4 (SMRB) Power switch off Below 1 Ω
      H3-3 (SMRP) - i3-3 (SMRP) Power switch off Below 1 Ω
      Text in Illustration
      *a

      Rear view of wire harness connector

      (to Power Management Control ECU)

      *b

      Rear view of wire harness connector

      (to Hybrid Battery Junction Block Assembly)

    6. Connect the hybrid battery junction block assembly connector.

    7. Install the upper hybrid battery cover sub-assembly Click here.

    8. Connect the power management control ECU connector.


    NG
    OK
  10. INSPECT HYBRID BATTERY JUNCTION BLOCK ASSEMBLY (SMRB)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Remove the hybrid battery junction block assembly Click here.

    3. B001LEPE01
      Text in Illustration
      *1 Hybrid Battery Junction Block Assembly

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      f2-1 (+) - S4-1 (CBI) Auxiliary battery voltage is applied between terminals i3-4 (SMRB) and i3-2 (GND). Below 1 Ω
    4. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      i3-4 (SMRB) - i3-2 (GND) -40 to 80°C (-40 to 176°F) 19.0 to 35.5 Ω
    5. Install the hybrid battery junction block assembly Click here.


    NG
    OK
  11. INSPECT HYBRID BATTERY JUNCTION BLOCK ASSEMBLY (SMRP)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Remove the hybrid battery junction block assembly Click here.

    3. B001N6XE01
      Text in Illustration
      *1 Hybrid Battery Junction Block Assembly

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      h2-1 (-) - S3-1 (CEI) Auxiliary battery voltage is applied between terminals i3-3 (SMRP) and i3-2 (GND). 28.5 to 31.5 Ω
    4. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      i3-3 (SMRP) - i3-2 (GND) -40 to 80°C (-40 to 176°F) 112 to 274 Ω
    5. Install the hybrid battery junction block assembly Click here.


    NG
    OK
  12. CHECK FOR INTERMITTENT PROBLEMS


    1. Check for intermittent problems Click here.

      Tech Tips


      • Since 2 trip detection logic is used, the DTC detection condition must be met twice.

      • If DTC P3004-131 is output again after performing the inspection, replace the inverter with converter assembly parts. If DTC P3004-131 is not output again, replace the hybrid battery junction block assembly.


    OK
    NG