HYBRID CONTROL SYSTEM, Diagnostic DTC:P0A0D-350, P0A0D-351

DTC Code DTC Name
P0A0D-350 High Voltage System Inter-Lock Circuit High
P0A0D-351 High Voltage System Inter-Lock Circuit High

DESCRIPTION


DTC No. INF Code DTC Detection Condition Trouble Are
P0A0D 350 Operating any of the safety devices with the vehicle stopped (ILK signal is ON) and turning the power switch on (IG)
  • Wire harness or connector

  • Power management control ECU

  • Service plug grip

  • Inverter with converter assembly

  • Frame wire

  • Inverter cover

P0A0D 351 Interlock signal line opens (ILK signal is ON) while the vehicle is being driven

WIRING DIAGRAM

B001KTNE02

CAUTION / NOTICE / HINT

CAUTION:


  • Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

  • After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work Click here.

    Tech Tips

    Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.

Note

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work Click here.

PROCEDURE


  1. CHECK DTC OUTPUT (HYBRID CONTROL)


    1. Connect the intelligent tester to the DLC3.

    2. Turn the power switch on (IG).

    3. Enter the following menus: Powertrain / Hybrid Control / DTC.

    4. Check if DTCs are output.

      Result
      Result Proceed to
      P0A0D only is output. A
      P0A1D is output. B
    5. Turn the power switch off.


    B
    A
  2. CLEAR DTC


    1. Connect the intelligent tester to the DLC3.

    2. Turn the power switch on (IG).

    3. Enter the following menus: Powertrain / Hybrid Control / DTC.

    4. Read and record the DTCs and freeze frame data.

    5. Clear DTCs and freeze frame data.

    6. Turn the power switch off.


    NEXT
  3. CHECK DTC OUTPUT (HYBRID CONTROL)


    1. Connect the intelligent tester to the DLC3.

    2. Turn the power switch on (IG).

    3. Enter the following menus: Powertrain / Hybrid Control / DTC.

    4. Check if DTCs are output.

      Result
      Result Proceed to
      P0A0D-350 or P0A0D-351 is output again. A
      Neither P0A0D-350 or P0A0D-351 is output again. B
    5. Turn the power switch off.


    B
    A
  4. CHECK SERVICE PLUG GRIP

    CAUTION:

    Be sure to wear insulated gloves.


    1. B001MPXE01
      Text in Illustration
      *1 Service Plug Grip

      Check if the service plug grip is installed correctly.

      Standard
      The service plug grip is fully pushed in as shown in the illustration.

      Note


      • Insert the service plug grip until a click sound is heard.

      • If "UNLOCK" is printed on the service plug grip, push in the service plug grip until "UNLOCK" is not visible at all.

      Tech Tips


      • For the removal and installation procedures Click here.

      • P0A0D-350 is also set if the power switch is turned on (IG) with the service plug grip removed. Confirm the conditions when the malfunction occurred.


    NG
    OK
  5. CHECK INVERTER COVER

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. B001LYD

      Check if the inverter cover of the inverter with converter assembly is installed correctly.

      OK
      The inverter cover is installed correctly.

    NG
    OK
  6. CHECK FRAME WIRE

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. B001LYD

      Remove the inverter cover from the inverter with converter assembly.

    3. B001LA2E02

      Check if the frame wire S1 is connected correctly.

      OK
      The frame wire connector is connected correctly.
    4. Install the inverter cover from the inverter with converter assembly.


    NG
    OK
  7. CHECK POWER MANAGEMENT CONTROL ECU


    1. B001LTE

      Disconnect connector A62 from the inverter with converter assembly.

    2. Turn the power switch on (IG).

    3. B001KWVE04
      Text in Illustration
      *a

      Front view of wire harness connector

      (to Inverter with Converter Assembly)

      Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Switch Condition Specified Condition
      A62-35 (ILKI) - Body ground Power switch on (IG) 10 to 14 V
    4. Turn the power switch off.

    5. Connect the inverter with converter assembly connector.


    NG
    OK
  8. CHECK INVERTER WITH CONVERTER ASSEMBLY (INTERLOCK)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. B001LTE

      Disconnect connector A62 from the inverter with converter assembly.

    3. B001LFYE03
      Text in Illustration
      *a

      Component without harness connected

      (Inverter with Converter Assembly)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      A62-35 (ILKI) - A62-36 (ILKO) Power switch off Less than 10 Ω

      Note

      Do not remove the inverter cover.

    4. Connect the inverter with converter assembly connector.


    NG
    OK
  9. CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - BODY GROUND)


    1. Install the service plug grip Click here.

    2. B001LTE

      Disconnect connector A62 from the inverter with converter assembly.

    3. B001LXHE04
      Text in Illustration
      *a

      Front view of wire harness connector

      (to Inverter with Converter Assembly)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      A62-36 (ILKO) - Body ground Power switch off Less than 1 Ω
    4. Connect the inverter with converter assembly connector.


    NG
    OK
  10. CHECK CONNECTOR CONNECTION CONDITION (INTERLOCK CIRCUIT)


    1. Check the connections of each connector.

      OK
      Dirt or foreign matter has not entered the connection, and there is no evidence of contamination.

    OK
    NG
  11. CHECK SERVICE PLUG GRIP


    1. Remove the service plug grip Click here.

    2. B001KL5E02
      Text in Illustration
      *1 Service Plug Grip

      Check the condition of the service plug grip interlock.

      OK
      Dirt or foreign matter has not entered the connection, and there is no evidence of contamination.
    3. B001MPXE01
      Text in Illustration
      *1 Service Plug Grip

      Install the service plug grip Click here.

      Note


      • Insert the service plug grip until a click sound is heard.

      • If "UNLOCK" is printed on the service plug grip, push in the service plug grip until "UNLOCK" is not visible at all.


    NG
    OK
  12. CHECK HARNESS AND CONNECTOR


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. B001MSOE03
      Text in Illustration
      *1 Inter Lock Connector

      Check that the interlock connector at the service plug grip installation socket is connected correctly.

      OK
      The connector is connected correctly.

    NG
    OK
  13. CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - SERVICE PLUG GRIP)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. B001LTE
      Text in Illustration
      *a

      Front view of wire harness connector

      (to Inverter with Converter Assembly)

      *b

      Front view of wire harness connector

      (to Service Plug Grip)

      Disconnect connector A62 from the inverter with converter assembly.

    3. Disconnect connector i2.

    4. Measure the resistance according to the value(s) in the table below.

      B001LL1E03
      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      A62-36 (ILKO) - i2-1 (ILK) Power switch off Below 1 Ω
    5. Connect the service plug grip connector.

    6. Connect the inverter with converter assembly connector.


    OK
    NG
  14. CHECK INVERTER COVER

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. B001LYD

      Remove the inverter cover from the inverter with converter assembly.

    3. B001LJ1

      Check the condition of the inverter cover interlock.

      OK
      Dirt or foreign matter has not entered the connection, and there is no evidence of contamination.
    4. Install the inverter cover from the inverter with converter assembly.


    NG
    OK
  15. CHECK FRAME WIRE (FRAME WIRE CONNECTOR)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. B001LYD

      Remove the inverter cover from the inverter with converter assembly.

    3. B001LA2E02

      Disconnect the frame wire S1 from the inverter with converter assembly.

    4. B001KV0

      Check the frame wire interlock.

      OK
      Dirt or foreign matter has not entered the connection, and there is no evidence of contamination.
    5. Connect the frame wire to the inverter with converter assembly.

    6. Install the inverter cover from the inverter with converter assembly.


    OK
    NG
  16. CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - INVERTER WITH CONVERTER)


    1. Turn the power switch off.

    2. B001LTE
      Text in Illustration
      *a

      Rear view of wire harness connector

      (to Power Management Control ECU)

      *b

      Front view of wire harness connector

      (to Inverter with Converter Assembly)

      Disconnect connector A62 from the inverter with converter assembly.

    3. Disconnect connector A19 from the power management control ECU.

      B001MUZE03
    4. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      A19-32 (ILK) - A62-35 (ILKI) Power switch off Below 1 Ω
    5. Connect the power management control ECU connector.

    6. Connect the inverter with converter assembly connector.


    OK
    NG