| DTC Code | DTC Name |
|---|---|
| P0A0D-350 | High Voltage System Inter-Lock Circuit High |
| P0A0D-351 | High Voltage System Inter-Lock Circuit High |
DESCRIPTION
When the power management control ECU detects that a safety device is operated, it will prohibit hybrid system operation or shut off the system main relay. There are three safety devices in three different locations. The first safety device is located at the service plug grip. The second one is located at the frame wire that is connected to the inverter with converter assembly. The third one is located at the inverter cover where the motor and generator cables and No. 2 engine wire (air conditioning harness) are connected to the inverter with converter assembly. If the service plug grip, inverter cover, or frame wire is removed, the interlock signal line will be open. If the vehicle is being driven, this condition will be determined to be an open circuit and the system main relays will not be shut off. If the safety devices are re-installed correctly, the system will return to normal when the power switch is turned on (IG).
| DTC No. | INF Code | DTC Detection Condition | Trouble Are |
|---|---|---|---|
| P0A0D | 350 | Operating any of the safety devices with the vehicle stopped (ILK signal is ON) and turning the power switch on (IG) |
|
| P0A0D | 351 | Interlock signal line opens (ILK signal is ON) while the vehicle is being driven |
WIRING DIAGRAM
CAUTION / NOTICE / HINT
CAUTION:
Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work Click here.
Tech Tips
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
Note
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work Click here.
PROCEDURE
CHECK DTC OUTPUT (HYBRID CONTROL)
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / DTC.
Check if DTCs are output.
| Result | ||||||
|---|---|---|---|---|---|---|
|
Turn the power switch off.
| B |
|
GO TO DTC CHART (P0A1D) Click here |
| A |
|
CLEAR DTC
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / DTC.
Read and record the DTCs and freeze frame data.
Clear DTCs and freeze frame data.
Turn the power switch off.
| NEXT |
|
CHECK DTC OUTPUT (HYBRID CONTROL)
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / DTC.
Check if DTCs are output.
| Result | ||||||
|---|---|---|---|---|---|---|
|
Turn the power switch off.
| B |
|
CHECK CONNECTOR CONNECTION CONDITION (INTERLOCK CIRCUIT) Click here |
| A |
|
CHECK SERVICE PLUG GRIP
CAUTION:
Be sure to wear insulated gloves.
| *1 | Service Plug Grip |
Check if the service plug grip is installed correctly.
| Standard |
|---|
| The service plug grip is fully pushed in as shown in the illustration. |
Note
Insert the service plug grip until a click sound is heard.
If "UNLOCK" is printed on the service plug grip, push in the service plug grip until "UNLOCK" is not visible at all.
Tech Tips
For the removal and installation procedures Click here.
P0A0D-350 is also set if the power switch is turned on (IG) with the service plug grip removed. Confirm the conditions when the malfunction occurred.
| NG |
|
INSTALL PARTS CORRECTLY |
| OK |
|
CHECK INVERTER COVER
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Check if the inverter cover of the inverter with converter assembly is installed correctly.
| OK |
|---|
| The inverter cover is installed correctly. |
| NG |
|
INSTALL PARTS CORRECTLY |
| OK |
|
CHECK FRAME WIRE
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the inverter cover from the inverter with converter assembly.
Check if the frame wire S1 is connected correctly.
| OK |
|---|
| The frame wire connector is connected correctly. |
Install the inverter cover from the inverter with converter assembly.
| NG |
|
INSTALL PARTS CORRECTLY |
| OK |
|
CHECK POWER MANAGEMENT CONTROL ECU
Disconnect connector A62 from the inverter with converter assembly.
Turn the power switch on (IG).
| *a | Front view of wire harness connector (to Inverter with Converter Assembly) |
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | ||||||
|---|---|---|---|---|---|---|
|
Turn the power switch off.
Connect the inverter with converter assembly connector.
| NG |
|
CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - INVERTER WITH CONVERTER) Click here |
| OK |
|
CHECK INVERTER WITH CONVERTER ASSEMBLY (INTERLOCK)
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect connector A62 from the inverter with converter assembly.
| *a | Component without harness connected (Inverter with Converter Assembly) |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
Note
Do not remove the inverter cover.
Connect the inverter with converter assembly connector.
| NG |
|
CHECK INVERTER COVER Click here |
| OK |
|
CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - BODY GROUND)
Install the service plug grip Click here.
Disconnect connector A62 from the inverter with converter assembly.
| *a | Front view of wire harness connector (to Inverter with Converter Assembly) |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
Connect the inverter with converter assembly connector.
| NG |
|
CHECK SERVICE PLUG GRIP Click here |
| OK |
|
CHECK CONNECTOR CONNECTION CONDITION (INTERLOCK CIRCUIT)
Check the connections of each connector.
| OK |
|---|
| Dirt or foreign matter has not entered the connection, and there is no evidence of contamination. |
| OK |
|
REPLACE POWER MANAGEMENT CONTROL ECU Click here |
| NG |
|
REPAIR OR REPLACE CONNECTOR |
CHECK SERVICE PLUG GRIP
Remove the service plug grip Click here.
| *1 | Service Plug Grip |
Check the condition of the service plug grip interlock.
| OK |
|---|
| Dirt or foreign matter has not entered the connection, and there is no evidence of contamination. |
| *1 | Service Plug Grip |
Install the service plug grip Click here.
Note
Insert the service plug grip until a click sound is heard.
If "UNLOCK" is printed on the service plug grip, push in the service plug grip until "UNLOCK" is not visible at all.
| NG |
|
REPLACE SERVICE PLUG GRIP Click here |
| OK |
|
CHECK HARNESS AND CONNECTOR
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
| *1 | Inter Lock Connector |
Check that the interlock connector at the service plug grip installation socket is connected correctly.
| OK |
|---|
| The connector is connected correctly. |
| NG |
|
INSTALL PARTS CORRECTLY |
| OK |
|
CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - SERVICE PLUG GRIP)
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
| *a | Front view of wire harness connector (to Inverter with Converter Assembly) |
| *b | Front view of wire harness connector (to Service Plug Grip) |
Disconnect connector A62 from the inverter with converter assembly.
Disconnect connector i2.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
Connect the service plug grip connector.
Connect the inverter with converter assembly connector.
| OK |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR (SERVICE PLUG GRIP - BODY GROUND) |
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - SERVICE PLUG GRIP) |
CHECK INVERTER COVER
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the inverter cover from the inverter with converter assembly.
Check the condition of the inverter cover interlock.
| OK |
|---|
| Dirt or foreign matter has not entered the connection, and there is no evidence of contamination. |
Install the inverter cover from the inverter with converter assembly.
| NG |
|
REPLACE INVERTER COVER Click here |
| OK |
|
CHECK FRAME WIRE (FRAME WIRE CONNECTOR)
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the inverter cover from the inverter with converter assembly.
Disconnect the frame wire S1 from the inverter with converter assembly.
Check the frame wire interlock.
| OK |
|---|
| Dirt or foreign matter has not entered the connection, and there is no evidence of contamination. |
Connect the frame wire to the inverter with converter assembly.
Install the inverter cover from the inverter with converter assembly.
| OK |
|
REFER TO REPLACE INVERTER WITH CONVERTER ASSEMBLY PARTS Click here |
| NG |
|
REPLACE FRAME WIRE Click here |
CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - INVERTER WITH CONVERTER)
Turn the power switch off.
| *a | Rear view of wire harness connector (to Power Management Control ECU) |
| *b | Front view of wire harness connector (to Inverter with Converter Assembly) |
Disconnect connector A62 from the inverter with converter assembly.
Disconnect connector A19 from the power management control ECU.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
Connect the power management control ECU connector.
Connect the inverter with converter assembly connector.
| OK |
|
REPLACE POWER MANAGEMENT CONTROL ECU Click here |
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |