CAMSHAFT OIL CONTROL VALVE INSPECTION

PROCEDURE


  1. INSPECT CAMSHAFT TIMING OIL CONTROL VALVE ASSEMBLY


    1. A004XRIE01

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 2 20°C (68°F) 6.9 to 7.9 Ω

      If the result is not as specified, replace the oil control valve assembly.

    2. Check the operation.


      1. A004YDOE13
        Text in Illustration
        *a Voltage Applied
        *b Voltage not applied

        Connect a positive (+) auxiliary battery lead to terminal 1 and a negative (-) auxiliary battery lead to terminal 2, and check the movement of the valve.

        Note

        Confirm that the valve moves freely and does not stick in any position.

        If necessary, replace the camshaft timing oil control valve assembly.

        Tech Tips

        Accumulation of foreign matter can cause minor pressure leaks. Minor pressure leaks will cause the camshaft to advance or retard, and this will cause a DTC to be stored.