| Item | Specified Condition |
|---|---|
| Standard value (for brand-new cap) | 94 to 122 kPa (1.0 to 1.2 kgf/cm2, 13.6 to 18 psi) |
| Minimum standard value (for used cap) | 94 kPa (1.0 kgf/cm2, 13.6 psi) |
| Item | Tester Connection | Specified Condition |
| IGCT relay Resistance |
3 - 5 | 10 kΩ or higher (No auxiliary battery voltage is applied across terminals 1 and 2) |
| 3 - 5 | Below 1 Ω (Auxiliary battery voltage is applied across terminals 1 and 2) |
| SMRB Resistance |
4 (SMRB) - 2 (GND) | 19.0 to 35.5 Ω (at -40°C (-40°F) to 80°C (176°F)) |
| SMRG Resistance |
1 (SMRG) - 2 (GND) | 19.0 to 35.5 Ω (at -40°C (-40°F) to 80°C (176°F)) |
| SMRP Resistance |
3 (SMRP) - 2 (GND) | 112 to 274 Ω (at -40°C (-40°F) to 80°C (176°F)) |
| Precharge resistor |
- | 28.5 to 31.5 Ω |
| Electric vehicle fuse | - | Below 1 Ω |
| Service plug grip | Always | Below 1 Ω |
| EV MODE switch | 3 (S) - 14 (E) | Below 1 Ω (EV MODE switch being pushed and held) |
| 10 kΩ or higher (EV MODE switch not pushed) |
||
| SPORT mode switch | 6 (PWR) - 14 (E) | Below 1 Ω (Mode switch being turned and held at SPORT position) |
| 10 kΩ or higher (Mode switch not turned) |
||
| ECO mode switch | 5 (ECO) - 13 (E) | Below 1 Ω (Mode switch being turned and held at ECO position) |
| 10 kΩ or higher (Mode switch not turned) |
||
| NORMAL mode switch | 4 (NORM) - 14 (E) | Below 1 Ω (Mode switch being pushed and held) |
| 10 kΩ or higher (Mode switch not pushed) |
||
| TRC OFF switch | 7 (+) - 14 (E) | Below 1 Ω (TRC OFF switch being pushed and held) |
| 10 kΩ or higher (TRC OFF switch not pushed) |
||
| Seat heater switch | 3 (RV) - 4 (SW) LH Side |
2.72 to 4.08 kΩ (Off) |
| 2.72 to 4.08 kΩ (On (Min.)) |
||
| 0.28 to 0.42 kΩ (On (Max.)) |
||
| 1 (REL1) - 6 (SW) | 2.72 to 4.08 kΩ (Off) |
|
| 2.72 to 4.08 kΩ (On (Min.)) |
||
| 0.28 to 0.42 kΩ (On (Max.)) |