NOISE FILTER INSPECTION

PROCEDURE


  1. INSPECT NOISE FILTER


    1. With the noise filter installed, check that there is no looseness or other abnormalities.

    2. Remove the noise filter.

    3. A004XHVE05
      Text in Illustration
      *a Noise Filter

      Measure the resistance of the noise filter according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 (+B) - 2 (GND) Always 10 kΩ or higher
      2 (GND) - 3 Always Below 1 Ω