WIRING DIAGRAM
| *a | from P/POINT Relay |
| *b | RAD NO. 2 |
| *c | Map Light Assembly |
| *d | Combination Meter Assembly |
CAUTION / NOTICE / HINT
Note
Inspect the fuses for circuits related to this system before performing the following inspection procedure.
PROCEDURE
CHECK HARNESS AND CONNECTOR (ILLUMINATION POWER SOURCE)
Disconnect the T6 map light assembly connector.
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | ||||||
|---|---|---|---|---|---|---|
|
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
CHECK HARNESS AND CONNECTOR (MAP LIGHT ASSEMBLY - COMBINATION METER ASSEMBLY)
Disconnect the T6 map light assembly connector.
Disconnect the H19 combination meter assembly connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
INSPECT MAP LIGHT ASSEMBLY
Remove the map light assembly Click here.
Connect 4 1.5 V dry-cell batteries in series.
| *a | Component without harness connected (Map Light Assembly) |
Connect a positive lead from the batteries to terminal 7 (ILL), and a negative lead to terminal 4 (LILL) of the map light assembly connector.
Check if the illumination for the emergency call switch comes on.
| OK |
|---|
| Illumination for the emergency call switch comes on. |
| OK |
|
REPLACE COMBINATION METER ASSEMBLY Click here |
| NG |
|
REPLACE MAP LIGHT ASSEMBLY Click here |